4 Mounting the optional CM-RC-01 extension kits

Required components and procedure to follow for
mounting the optional extension kits of the compressor
module add-on kit:
• Mounting and connecting valve flanges and solenoid
valves for capacity control (CRII) and/or start unload-
ing (SU).
• Mounting and connecting the pressure transmitters.
• Mounting and connecting the liquid injection.
• Mounting and connecting the additional fan.
WARNING
The compressor is under pressure!
Serious injuries are possible.
Depressurize the compressor!
Wear safety goggles!
After mounting new components such as discharge gas
temperature sensor, pressure transmitter, injection
nozzle or injection valve:
10
WARNING
Serious injuries are possible. New component
may suddenly become detached.
Check the thread.
Carefully screw in the new component. Observe
the tightening torques!
Perform a tightness test before commissioning!
4.1 Mounting the extension kit "Capacity
control" (CRII) and "Start unloading" (SU)
Information
In order to allow the solenoid valves for capacity
control (CRII) and start unloading (SU) to be
mounted, the corresponding CRII and SU cylin-
der heads must already be pre-installed on the
compressor.
For safety references and installation descrip-
tions for the CRII or SU cylinder heads, includ-
ing mounting positions and exact equipment of
the cylinder banks, see Technical Information
KT-101 and KT-110.
• Remove the oval flange and seal from the
CRII/SU cylinder head and clean the sealing
surface.
• Apply a new seal, paying attention to the
guide pin positions!
• Use new screws to fasten the solenoid valve.
Alternately tighten the screws (tightening
torque 80 Nm).