3.
Put the fan heater on the supporting wheel frame.
Make sure the fan heater air inlet (at the back) is
above the wheels. The holes on the fuel tank flange
must match the holes on the supporting wheel frame.
4.
Put the front and back handle on the fuel tank flange.
Put the screws through the handles, fuel tank flange
and supporting wheel frame. After inserting the
screw, tighten the given nut by hand.
5.
Tighten the nuts if all screws are inserted.
Safety equipment
The oil hot-air turbine is fitted with an electronic flame
control. The appliance is stopped in case of operating
failure. If the oil hot-air turbine is overheated, thermostat
preventing overheating is activated, which interrupts the
fuel supply; the thermostat is automatically deactivated if
the combustion chamber temperature drops below the
accepted maximum value. The overheating cause must be
identified and removed (e.g. air inlet and outlet blocking or
fan stopping) before putting the oil hot-air turbine back into
operation. To start the appliance again, please follow the
instructions included under "PUTTING THE APPLIANCE
INTO OPERATION".
Behaviour in case of emergency
Provide necessary first aid treatment corresponding to the
injury nature and seek qualified medical help as soon as
possible.
Protect the injured person from other injuries and calm
him/her down.
First aid kit must always be available in the place of
your work in case of accident in accordance with DIN
13164. Material taken out of the first aid kit needs to be
supplemented right away.
If help is needed,
please provide the following details:
1.
Place of accident
2.
Accident nature
3.
Number of injured persons
4.
Injury type
Operating staff requirements
The operator must carefully read the Operating
Instructions before using the appliance.
Qualification
No special qualification is necessary for using the
appliance apart from detailed instruction by a qualified
person.
Minimum age
The appliance may only be operated by persons over 16
years of age. An exception includes youngsters operating
the appliance within their professional education to
achieve necessary skills under teacher's supervision.
Training
Using the appliance only requires appropriate instructions
by a professional or reading the Operating Instructions. No
special training necessary.
Putting the appliance into operation
Before putting the oil driven fan heater into operation and
plugging it, check if the network characteristics correspond
to the values specified on the type label.
WARNING:
RCD 30mA (safety switch against stray current) must
be integrated to the electrical circuit to which the oil
driven fan heater is connected.
Follow all safety measures.
Add oil to the fuel tank. Close the fuel tank lid again.
Connect the fan heater feeder cable to a standardised
outlet with a protective pin.
To put the appliance into operation, the following is
needed:
Putting ON/OFF to the ON symbol position ("I"): The fan
starts and combustion gets switched on after several
seconds.
Thermostat:
Use the thermostat to set the required room temperature.
The required value on the left display (pic. A/b) will change
by turning the thermostat controller (pic. (A/a). A/b). The
right display (pic. A/c) shows the approximate current
room temperature measured on the fan wheel.
After reaching the set temperature, the oil driven fan
heater is automatically switched off. If it gets below the set
temperature, the oil driven fan heater is automatically
switched on again.
Example of use:
"II" (pic. A/d)
15°C actual temperature (pic. (A/b))
20°C temperature required (pic. A/c).
The oil driven fan heater is now able to heat the "space" to
20°C and then is automatically switched off. If the
appliance remains in the emergency position, the oil driven
fan heater is automatically switched on again when it is
below the required temperature.
Example of use:
18°C actual temperature (pic. A/c)
temperature required (pic. A/b).
heater now gets switched off. If the appliance remains in
the emergency position, the gas heating fan is
automatically switched on when it is below 15°C.
It may take a few seconds before combustion is started in
case of the first starting or after the oil driven fan heater
has not been used for a long time.
To switch the appliance off, the following is needed:
Put ON/OFF (pic. A/d) to the OFF symbol position ("0"). Or
the set temperature (pic. A/b) must be set lower than the
current room temperature (pic. A/c).