3.2. Defining the dimensions for outward opening -
Fig. 5
No.
A-B
Dimension to determine the mounting point of the pillar
mounting bracket
Attention
Maximum opening 90°.
3.3. Installing the pillar mounting bracket
To facilitate taking measurements, use the Access Fix&GO Pro appli-
cation.
Fasten the pillar mounting bracket in compliance with dimension A defined
(either by the Access Fix&GO Pro application or by the dimensions chart):
- Screw bracket - Fig. 6a
- Welded bracket - Fig. 6b
3.4. Installing the gate leaf mounting bracket - Fig. 7
1) Unlock the motors.
2) Fit the cylinder on the pillar mounting bracket.
3) Insert the pillar mounting bracket-motor connecting pin.
4) Install the gate leaf mounting bracket on the cylinder.
5) Secure the gate leaf mounting bracket, ensuring that the cylinder is
correctly levelled.
4. MOTOR ELECTRICAL CONNECTION
FIG. 8
1) Connect the motors to the control box.
2) Refit the motor covers (Fig. 9).
5. LOCKING/UNLOCKING THE MOTORS
When unlocking the motors, the gate may be manoeuvred manually if
there is an electrical fault (Fig. 10).
6. SETTING THE END LIMITS FIG. 11
This operation must be performed between steps 1 and 2 of the au-
to-programming process described in the installation manual of the
CONTROL BOX 3S.
1) Unlock the motors.
2) Loosen the bolt and remove the upper end piece at the end of the mo-
tor.
3) Slide and remove the upper section of the motor.
4) With the gate closed, move the closing end limit until the LED is lit to
indicate that it is correctly positioned.
5) Tighten the closing end limit (do not use a magnetic screwdriver).
6) With the gate open, move the opening end limit until the LED is lit to
indicate that it is correctly positioned.
7) Tighten the opening end limit (do not use a magnetic screwdriver).
If the spandrel is small making it impossible to adjust the open-
ing end limit, adjust the end limit with dimension A+B+15  mm.
This dimensions gives an indication of the position of the opening end
limit at 90°. If the desired opening is not satisfactory, move the opening
end limit in one direction or the other.
8) Refit the upper section of the motor by sliding it until it hits the plastic
part or by snapping it into place on top of the motor
9) Refit the upper end piece on the end of the motor and tighten.
10) Lock the motors.
11) Start the auto-programming process (see installation manual of the
CONTROL BOX 3S).
©
Copyright
2017 SOMFY ACTIVITES SA. All rights reserved.
Description

7. TECHNICAL DATA

General specifications
Power supply
Max. power consumption
Rotation speed
Power consumption
Traction and pushing force
Working stroke
Minimum distance behind the gate
Maximum hinge offset
Rod speed
Manual manoeuvring
Use
Installation
Operating temperature
Index protection rating
Lubrication
EN
24 V
40 W
3800 rpm
1.5 A
2000 N
465 mm
160 mm
183 mm
17 mm/s
Using an individual key
Intensive
residential/collective
-20°C to +60°C
IP44
Permanent grease
5