Metrix CX 1651 Manuel De L'utilisateur page 104

Calibrateur multifonctions

Publicité

Les langues disponibles

Les langues disponibles

Calibrateur multifonctions CX 1651
value of R0 resistance and the type of resistance temperature sensor
cold junction temperature of TC sensors and the selected type of TC sensor
value of amplitude and shape type for frequency function
f)
Information section
The information section located in the right part of the display displays additional information related to
the selected function:
symbol of connected
At the same time, a LED located above the OUTPUT button is lit.
information about remote/local control of the calibrator. If the calibrator is controlled remotely,
REM is displayed. If the calibrator is controlled locally using the keyboard, LOCAL is displayed.
information about the use of 50-turn coil (COIL x50) at the current output of the calibrator, if this
feature is turned on using the SETUP menu.
information about the type of connected cable adapter, if used
information about the grounding method of output terminals: GND I, GND U as set up using the
setup menu.
g) Information about the uncertainty of the output signal
This section displays the maximum error of the main value of the output signal. The value is calculated
using the main specification listed in the User's Manual and it is displayed in %.
5.
INPUT section
This section displays the values measured by the multimeter. The section includes following data:
a) Main value of measured signal
This line displays the measured value and the unit of measurement. If the input signals exceed the
permitted range, OVERFLOW is displayed.
b) Designation of selected function of the multimeter
Symbolic display of selected function of the multimeter: V DC, mA DC, mV DC, R 4W, Freq, T TC, T
RTD, SGS, ACAL.
6.
Display buttons section
This line displays the symbolic descriptions which define the meaning of four related display buttons. The
respective meanings are as follows:
symbol
button function
x 10
increase set value 10 x
: 10
decrease set value 10 x
Shape
selection of signal shape
+/-
reversed polarity of output voltage and current
EXIT
move up one level
Calib.
enter the calibration menu
SETUP
enter the setup menu
TC type
selection of thermocouple sensor type
RTD type
selection of resistance temperature sensor type
f
enter the frequency of the signal
MODE
select the unit of measurement
104
or disconnected
output terminals.
note
only for U, I, F functions
only for DC U, DC I functions
only for F, P-E functions
only for T function
only for T function
only for U, I function
only for AC P-E function