8. Identification - Rating plate data (Fig. 3)
M Medium
P Power
2 Multisystem, 2nd generation
B Compressors brand
O Oil equalizer
B Plant configuration
S Pressure switches
Power Supply
D Field of use
4 Gas
C Lower part control device
Control panel accessories:
TN/BT if single plant;
TN if dual;
lower if multi-floor
No. compressors:
TN/BT if single plant;
2
TN if dual;
lower if multi-floor
4
N
Compressor model
C
located on lower floor
1
2
/
Upper part control device
C
if multi-floor
Control panel accessories
upper part
2 No. compressors, upper part
4
N
Compressor model
C
located on upper floor
1
2
05060107 00 03/02/2010
DESCRIPTION OF THE PLANT CODE FOUND ON THE RATING PLATE
B=Bitzer; C=DWM-Copeland DISCUS; D=Dorin; F=Frascold; S=Copeland Scroll
0="BOLS" standard equalization
3=Equalization with tube and oil separation with suction discharge
4=MECHANICAL oil level regulators with separator and oil reserve
5=ELECTRONIC oil level regulators with separator and oil reserve
6=ELECTRONIC oil level regulators with separator and incorporated oil reserve
(see at pag. 9-10)
_ = NO Pressure switches/ Transducers / Manometers
A = Pressure switches + Transducers
B = Pressure switches + Manometers
C = Mechanical Back-up + Pressure switches + Transducers + Manometers
D = Electronic Back-up + Pressure switches + Transducers
E = Electronic Back-up + Pressure switches + Transducers + Manometers
F = Pressure switches + Transducers + Manometers
M = Only Manometers
P = Only Pressure Switches
S = Mechanical Back-up + Pressure switches + Transducers
T = Only Transducers
W = Pressure switches + Transducers (WURM version)
_ = 400-3-50; I= 240-3-50; E= 460-3-60; V= 240-3-60; W= 380-3-60
B=BT
D=DUAL Same floor
M=DUAL Multi-floor
N=TN
S=SEPARATE units ( TN Below - BT Above)
4=R-404A; 5=R-507A
C=CAREL pCo3; E=DANFOSS EKC331; I=CAREL IR32Z; K=DANFOSS AKPC530 (prev. EKC531); L=DIXELL XC1015D; P=DANFOSS AK2-
PC
_=Standard
A=Special
D=Differentials
E=Monitor + Differentials
F=Monitor + Differentials + Inverter (only plant)
G=Monitor + Differentials + Inverter (also on condenser)
H=Monitor + Differentials + Power Factor Correction
I=Inverter only in plant
L=Inverter also on condenser
M=Monitor
N=Monitor + Inverter (only plant)
O=Monitor + Inverter (also on condenser)
P=Monitor + Power Factor Correction + Inverter (only plant)
Q=Monitor + Power Factor Correction + Inverter (also on condenser)
R=Power Factor Correction
S=Monitor + Power Factor Correction
T=Differentials + Power Factor Correction
U=Differentials + Inverter (only plant)
V=Power Factor Correction + Inverter (only plant)
Z=Differentials + Inverter (also on condenser)
J=Power Factor Correction + Inverter (also on condenser)
K=Differentials + Power Factor Correction + Inverter (also on condenser)
W=Differentials + Power Factor Correction + Inverter (only plant)
X=Monitor + Differentials + Power Factor Correction + Inverter (only plant)
Y=Monitor + Differentials + Power Factor Correction + Inverter (also on condenser)
2; 3; 4
C=CAREL pCo3; E=DANFOSS EKC331; I=CAREL IR32Z; K=DANFOSS AKPC530 (prev. EKC531); L=DIXELL XC1015D; P=DANFOSS AK2-
PC
See control panel accessories
2; 3; 4
MPM2 - Medium Power Multisystem
English
27