Technical Data
Standard signal input
for correction variable or
disturbance variable mA
(X1.16 ... X1.14):
Standard signal output mA
(X1.13, X1.12):
Digital input (X1.10, X1.9
and X1.7, X1.6):
Position feedback input
(X1.3 ... X1.1):
Power relay output for
controlled variable output (M, R)
or limit value signalling (G)
(XR1 and XR2):
Power relay output
for alarm triggering (XR3):
32
Galvanically isolated from other inputs and outputs
Insulation voltage:
Input range:
Input resistance:
Accuracy:
Resolution:
Supply voltage and current for external electronics:
Galvanically isolated from other inputs and outputs
Insulation voltage:
Output range:
Max. load:
Accuracy:
Common reference potential and with RS interface but galvanically
isolated from remaining inputs and outputs
Insulation voltage:
- Pause
- Disturbance variable up to 10 Hz or up to 500 Hz
(according to identity code/programmable)
Galvanically isolated from other inputs and outputs
Insulation voltage:
Potentiometer to be connected: 900 Ω...10 kΩ
Accuracy (not including potentiometer error):
Resolution: 0.5 % of input range
Actuating time:
Type of contact:
Load capacity:
Contact lifespan:
Type of contact:
Load capacity:
Contact lifespan:
500 V
0/4...20 mA (programmable)
50 Ω
0.5 % of input range
0.014/0.012 mA
22 V ±1.5 V, 20 mA
500 V
0/4...20 mA (programmable)
600 Ω current output 1
400 Ω current output 2
0.5 % of output range referred to displayed value
500 V
(given closed contact)
500 V
1 % of input range
min.:
25 s
max.: 180 s
Changeover contact, noise-suppressed
with varistors
250 V AC, 3 A, 700 VA
>20 x 10
6
switching operations
Changeover contact, noise-suppressed
with varistors
250 V AC, 3 A, 700 VA
6
>20 x 10
switching operations