Initial start-up
In order to perform the initial start-up, the following steps are
required:
– Switch on power supply.
12 V direct voltage for CP plus control panel and Combi and
230 V mains voltage for air conditioning systems and Combi E.
– Start the search of the appliances under the menu item
"Service menu" –> "RESET" –> "PR SET".
After confirmation,Truma CP plus control panel initialises it-
self. "INIT .." appears on the display while this is in progress.
This stores in the Truma CP plus control panel the appliances
that have been found.
Start-up
Start / Stand-by screen
After connecting the Truma CP plus control panel to the power
supply, a start screen is displayed after a few seconds.
– The display changes between the time and the set
room temperature.
– Special displays on command via Truma App, IR re-
mote control of the air conditioning system or CI BUS
(see "Special displays" on page 37).
– After a repair / retrofit, the procedure described under
"Initial start-up" must be repeated.
Functions
The functions in the menu bars (3, 4) of the Truma CP plus con-
trol panel are selectable in any order. The operating parameters
are shown on the status bar (2) and on the displays (5, 6).
Select setting level
– Tap the rotary push button.
The display shows the setting level. The first icon flashes.
Switching on and off
Switching on
– Tap the rotary push button.
– Previously set values / operating parameters are reac-
tivated after switching on.
Switching off
– Press rotary push button for longer than 4 seconds.
– "APP"
appears in the display after 2 seconds.
1
– "OFF" appears after another 2 seconds.
– The Truma CP plus control panel plus deactivation pro-
cedure can be delayed by several minutes because of
internal heating or air conditioning system after-runs.
Only in conjunction with an iNet Box.
1
27