Initial start-up

In order to perform the initial start-up, the following steps are
required:
– Switch on power supply. 12 V
control panel, Truma VarioHeat and Truma E-Kit and 230 V
for air conditioning systems and Truma E-Kit.
– Start the search of the appliances under the menu item
"Service menu" -> "RESET" -> "PR SET".
After confirmation, the Truma CP plus VarioHeat control panel
initialises itself. "INIT .." appears on the display while this is in
progress. The devices that have been found are stored in the
control panel.

Start-up

Start / Stand-by screen
After connecting the Truma CP plus VarioHeat control panel
to the power supply, a start screen is displayed after a few
seconds.
Fig. 6
– The display changes between the time and the set
room temperature.
– Special displays on command via IR remote control
of the air conditioning system or CI-BUS (see "Special
displays" on page 34).
– After a repair / retrofit, the procedure described under
"Initial start-up" must be repeated.
for Truma CP plus VarioHeat

Functions

The functions in the menu bars (3, 4) of the
Truma CP plus VarioHeat control panel are selectable in any
order. The operating parameters are shown on the status
bar (2) and on the displays (5, 6).

Select setting level

– Tap the rotary push button.
The display shows the setting level. The first icon flashes.
Fig. 7

Switching on/off

Switching on
– Tap the rotary push button.
Previously set values / operating parameters are reacti-
vated after switching on.
Switching off
– Press the rotary push button for longer than 4 seconds.
The Truma CP plus VarioHeat control panel deactivation
procedure can be delayed by several minutes because of
internal heating or air conditioning system after-runs ("OFF" is
shown on the display during this time).
25