APP mode in conjunction with an iNet Box
Operation
In APP mode, the connected appliances and the
Truma CP plus control panel go into Stand-by.
– No heating function.
– No hot water heating.
– No operation of the air conditioning system.
– No time switch function in the Truma CP plus control panel.
– The CP plus control panel remains ready to receive com-
mands via the Truma app or the infrared remote control of
the air conditioning system. This means that the connected
appliances remain operable via the Truma App or the air
conditioning system's infrared remote control.
Activating APP mode
– Press the rotary push button for about 2 seconds until "APP"
appears in the display.
– Release the rotary push button.
– The previously set values are saved.
Ending APP mode
APP mode is ended
– when new values are determined via the Truma App or the
air conditioning system's infrared remote control.
– when the Truma CP plus control panel is woken by pressing
the rotary push button. The previously saved values are then
accepted for renewed operation.
28
Change room temperature
– Select icon in menu bar (3) with rotary push button.
– Change to the setting level by tapping on the rotary push
button.
– Depending on the appliance that is connected, select between
heating system (HEATER) or air conditioning system (AC) or
automatic air conditioning system
push button.
– Tap rotary push button to confirm selection.
– Select desired temperature with rotary push button.
– Tap the rotary push button to confirm the value.
a
b
c
Heater (HEATER)
settable temperature range 5 – 30 °C (1 °C increments)
a = Heater
– Heater is switched on.
2
The temperature range below 5 °C (OFF) must be selected
in order to switch off the heater.
Automatic climate control (AUTO) only if "ACC" has been activated
1
in the service menu (see "Service menu" on page 35). The factory
default setting is "deactivated".
Symbol flashes until the desired room temperature is reached.
2
(AUTO) using the rotary
1
d
f
e
2
3