Special Measures
Always wear protective glasses when working with
the device for cutting the tiles. Use respirator and
protective glasses for protection of your health
against the danger that may occur at cutting
operation.
Never expose the electric devices to rain. The
asbestos containing material shall not be treated.
Before every use test the device, the cable and
diamond wheel if they are not damaged. The damage
shall be immediately removed only by an authorized
service workshop. The plug may be put into the
socket only if the device is off.
13

Putting into Operation

Before every putting into operation the cutting device shall
be fixed to the working table with three screws and three
prepared holes in the working table.
14
Switching-on – Switching.off
Switching-on:
Put the switch (6) into „I" position, the
device will be switched-on. The device
will remain in operation until switched-
off. In case of voltage failure the
device will switch off automatically.
The device will be re-switched on
again by putting the switch into „I"
position
Switching-off:
Put the switch into „O" position, the
device will switch-off.
Operation with a protection switch against insufficient
current (Fig.B)
Operation:
• Protection switch against insufficient current shall be
connected by means of a socket and device plug shall be
inserted into its socket.
CAUTION Before every putting into operatiom the
function shall be checked:
Push the„TEST" key (t): Integrated fuse FI shall be
desactivated and it must be heard.
Push the taste „RESET" (v): Integrated fuse FI shall be
activated and you must hear it.
CAUTION! As soon as the FI fusion is activated, the
control lamp will light up (s). It will be out in case of
shortcut, failure of power or when the mains plug has
been pulled out.
CAUTION! Never switch the device on before checking
the function!
Only after the function has been checked the device is
ready to operation.
• After switching on: Push the switch (6)
into „I" position.
• After switching off: Push the switch (6)
into „O" position.
CAUTION! The switch (6) on the device shall be
pushed into „0" position in case of any failure of the
function or at any putting out of operation, so that the
motor cannot be switched on unintentionally.
15

Technical Data

Input power:
Voltage:
Frequention:
Number of idle revolutions:
Diamond div.wheel dia:
Table size:
Max. cutting height:
Sound emmission/vibration:
Weight:
For safety reasons protection earphones
and eye protector are recommended in any
case!
16
Maintenance, Cleaning
Pull out mains plug before starting any works on the device.
Clean the device with a damp cloth soaked with a bit of soft
soap. Do not use detergents and dissolvents, they may
damage the devices made of plastic. Clean carefully the
table after every use and protect it against corrosion by
wiping it with a cloth slightly soaked with oil..
17
Warranty
The claims on warranty provision according to the
enclosed warranty sheet.
600 W / S2:30 min
230 V
50 Hz
2950 min-1
180 mm x 25,4 mm
330 mm x 360 mm
34 mm
LpA=91,8 dB(A),
LwA=104,8 dB(A)
about. 9 kg