Pump Design - Xylem Lowara e-MPV Manuel D'installation, D'exploitation Et De Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
Snow making
Nanofiltrations
Boiler feed
Improper use
WARNING:
Improper use of the pump may create
dangerous conditions and cause
personal injury and damage to property.
An improper use of the product leads to the loss
of the warranty.
Examples of improper use:
Liquids not compatible with the pump
construction materials
Hazardous liquids, such as toxic, explosive,
flammable, or corrosive liquids
Potable liquids other than water, for
example, wine or milk
Examples of improper installation:
Hazardous locations, such as explosive, or
corrosive atmospheres.
Location where the air temperature is very
high or there is poor ventilation.
Outdoor installations where there is no
protection against rain or freezing
temperatures.
DANGER:
Do not use this pump to handle
flammable or explosive liquids, or both.
NOTICE:
Do not use this pump to handle liquids
containing abrasive, solid, or fibrous
substances.
Do not use the pump for flow rates beyond
the specified flow rates on the data plate.
Special applications
Contact the local sales and service representative
in the following cases:
If the density or viscosity value of the
pumped liquid exceeds the value of water,
such as water with glycol; as it may require a
more powerful motor.
If the pumped liquid is chemically treated, for
example softened, deionized, demineralized
etc..
Any situation that is different from the ones
that is described and relate to the nature of
the liquid.
3.2 Pump denomination
See
Figure 2
for an explanation of the
denomination code for the pump and one example.
3.3 Nameplate
The nameplate is located on the motor adapter.
The nameplate lists key product specifications.
For more information, see
The nameplate provides information regarding
the impeller and casing material, the mechanical
seal and their materials. For more information,
see
Figure
2.
Figure
1.
IMQ or TUV or IRAM or other marks (for
electric pump only)
Unless otherwise specified, for products with a
mark of electrical-related safety approval, the
approval refers exclusively to the electrical pump.

3.4 Pump design

Suction casing: vertical with radial flange
Discharge casing: vertical with radial flange
Impeller design closed with no axial thrust
balancing
Balancing drum at discharge side
incorporated in discharge casing
Motors – Design IEC
Standard: IE3 for Europe and NEMA
Flanges according to EN1092 / ISO 7005,
PN 10/16, 25, 40 and 63. Optional drilled
flanges according to ASME B16.5; Class
150, 300 and 600
Couplings: flexible without spacer as
standard.
Coupling guard: totally enclosed
3.5 Material
The metallic parts of the pump that come in contact
with water are made of the following:
Item
Impeller
Diffuser
Casing
Shaft
Shaft
sleeve
Relief
pipe
Plain bearing
3.6 Mechanical seal
Standard mechanical seal according to
EN12756
Cartrige seal
Soft packing
en - Original instructions
Material Code
Tungsten Carbide
17