Installing The Unit - AVG TEXAS AVT-309CS2 Instructions D'installation Et Guide De L'usager

Hotte murale
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLING THE UNIT 
 
Figure 1 
Fig. 3a 
Fig. 4 
 
Step 1:    Mark the leveling point of the hood. Position two mounting 
screws on the wall, leaving 1/8" off the wall. 
 
Step 2
Measure the width of the chimney then attach the chimney 
:   
mounting brackets to the wall at the desired height, taking 
into  account  the  minimum  clearance  between  the  hood 
and the cooking surface (see installation drawing on page 
20
 
Step 3:
Align hood‐mounting holes to the screws on the wall and 
   
hook the hood into place. Tighten screws to secure hood to 
the wall. CAUTION: Make certain the range hood is secure 
before releasing
 
 
 
Fig. 3b 
Step 5:    Plug the power cord into the socket (see Figure 4).
   
   
 
 
                             
 
 
).
Step 4: Slide a 6" round metal venting tube over 
the  adapter  /  plug  (see  Figures  3a  or  3b). 
Seal the joints with metal tape
 
 
 