INSTALLATION
Installation
EBK 5 G and EBK 5 GA
f Attach the tap outlet.
f
f Attach the wall mounting using the washers and screws
f
supplied.
f Align the wall mounting using a spirit level. Take care to ob-
f
serve the height specification. In the event of unevenness on
the wall, the wall mounting can be attached using additional
screws at the bottom.
f Slide the appliance from above down onto the wall mounting
f
bracket and the tap fitting so it is properly aligned.
f Tighten the fixing screws and the compression fitting.
f
f Attach the overflow/steam pipe.
f
10.2 Alternative installation methods
10.2.1 Water connection on finished walls with washing
machine and dishwasher connection (WAS valve)
EBK 5 G
1
2
1 Twin connector
2 Plastic sleeve
3 WAS valve
f Trim the twin connector and the plastic sleeve to the right
f
lengths.
EBK 5 GA
115
+15
1
1 WAS valve
20
| EBK G | EBK GA
115
+15
3
10.2.2 Attaching the overflow/steam pipe to finished walls
Note
With these connections, the overflow/steam pipe must
be fixed to the wall.
EBK 5 G
180 - 250
140
1 Outlet pipe to the sink
EBK 5 GA
180 - 250
140
1 Outlet pipe to the sink
1
1
www.stiebel-eltron.com