INSTALLATION
Initial start-up
10.2.3 Attaching the overflow/steam pipe to unfinished walls
Note
With these connections, the overflow/steam pipe must
be fixed to the wall.
EBK 5 G
180 - 250
140
1 Drain outlet with stench trap
EBK 5 GA
180 - 250
140
1 Drain outlet with stench trap
www.stiebel-eltron.com
1
1
10.3 Power supply
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
Installation with a permanent power cable is not per-
mitted.
When permanently connected to the power supply using
an appliance wall socket, the appliance must be able to
be separated from the mains power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
Material losses
!
Observe the type plate. The specified voltage must match
the mains voltage.
Note
Ensure that the appliance is earthed.
When connecting the appliance via a standard socket, ensure that
this is easily accessible once the appliance has been installed.
11. Initial start-up
1
4
1 White-coated two-handled lever tap with throttle screw
2 Chrome-coated three-handled tap with throttle screw
3 Throttle screw for flow rate: maximum throttle
4 Throttle screw for flow rate: no throttle
f Adjust the flow rate. For this, observe the maximum permis-
f
sible flow rate with a fully opened tap (see chapter "Specifi-
cation / Data table"). If necessary, reduce the flow rate using
the throttle screw.
f Fill the appliance via the tap fitting. Observe the maximum
f
nominal capacity (see chapter "Specification / Data table").
f Turn the temperature selector to the required temperature.
f
f Press the temperature selector.
f
f Check the function of the appliance.
f
f Draw off hot water via the tap.
f
f Remove the protective foil from the user interface.
f
2
3
EBK G | EBK GA |
21