Installation according to EMC (installation of a CE−typical drive system)
L1
L2
L3
N
PE
PES
PES
IN1
X11
IN2
K31
IN3
K32
IN4
33
34
PES
PES
X5
28
E1
E2
E 3
E4
E5
+
ST1
DC 24 V
ST2
–
39
A1
A2
A3
A4
59
PES
PES
T1 T2
Fig. 5−1
EDKVS9332X DE/EN/FR 4.0
F1 ... F3
K10
PE
Z2
PE L1 L2 L3
X4
HI
LO
GND
PES
X6
63
7
62
7
4
3
EVS9321 ...
2
EVS9332
1
PES
X7
X8
X9
X10
PE U
V
W
-UG
+UG
PE
PES
PES
J>
PES
M
PE
3~
Example for wiring in accordance with EMC regulations
F1 ... F3
Fuses
K10
Mains contactor
Z1
Programmable logic controller (PLC)
Z2
Mains choke or mains filter
Z3
EMB9351−E brake module
S1
Mains contactor on
S2
Mains contactor off
+U
, −U
DC−bus connection
G
G
PES
HF shield termination through large−surface connection to PE
l
Electrical installation
PES
X7/8
X7/9
KTY
PES
PES
M
PE
3~
S2
S1
K10
K10
PES
PES
PES
PES
PES
PE
PE
-UG
+UG
T1
T2
RB
JRB
PES
9351
Z3
9300std072
5