3
Technical data
Rated data
Operation at 480 V
9300
Mains current
With
mains choke
Type
I
[A]
r
EVS9321−xx
1.5
EVS9322−xx
2.5
EVS9323−xx
3.9
EVS9324−xx
7.0
EVS9325−xx
12.0
EVS9326−xx
20.5
EVS9327−xx
27.0
EVS9328−xx
44.0
EVS9329−xx
53.0
EVS9330−xx
78.0
EVS9331−xx
100
EVS9332−xx
135
Bold print = Lenze setting
1)
Mains currents at 8 kHz switching frequency
2)
Switching frequency of the inverter
3)
Power which can additionally be drawn from the DC bus at operation with power−adapted motor
9300
Rated current
Type
I
[A]
r8
EVS9321−xx
1.5
EVS9322−xx
2.5
EVS9323−xx
3.9
EVS9324−xx
7.0
EVS9325−xx
13.0
EVS9326−xx
22.3
EVS9327−xx
30.4
EVS9328−xx
44.7
EVS9329−xx
56.0
EVS9330−xx
84.0
EVS9331−xx
105
EVS9332−xx
125
Bold print = Lenze setting
1)
Switching frequency of the inverter
2)
The currents apply to a periodic load change cycle with max. 1 minute overcurrent duration and 2 minutes base load
duration at max. 75 % I
126
1)
Typical motor power
Without
ASM
mains choke
(4−pole)
I
[A]
P
[kW]
r
r
2.1
0.37
3.5
0.75
5.5
1.5
˘
3.0
16.8
5.5
˘
11.0
43.5
18.5
˘
30.0
˘
37.0
˘
45.0
˘
55.0
˘
90.0
1)
8 kHz
Maximum
Standstill current
2)
current
I
[A]
I
M8
08
2.25
2.3
3.75
3.8
5.85
5.9
10.5
10.5
19.5
19.5
33.5
22.3
45.6
30.4
67.1
44.7
84.0
49.0
126
72.0
157.5
105
187.5
111
r
l
Output power
2)
8 kHz
U, V, W
P
[hp]
S
[kVA]
r
r8
0.5
1.2
1.0
2.1
2.0
3.2
4.0
5.8
7.5
10.8
15.0
18.5
25.0
25.0
40.0
37.0
50.0
46.6
60.0
69.8
75.0
87.3
125
104
Output currents
Rated current
[A]
I
[A]
r16
1.1
1.8
2.9
5.2
9.7
14.5
19.2
28.2
35.0
55.0
65.0
80.0
Power loss
3)
+U
, −U
G
G
P
[kW]
P
[W]
DC
V
2.0
100
0.75
110
2.2
140
0.75
200
0
260
0
390
12
430
4.8
640
0
810
6
1100
0
1470
6
1960
1)
16 kHz
Maximum
Standstill current
2)
current
I
[A]
I
[A]
M16
016
1.65
1.7
2.7
2.7
4.35
4.4
7.8
7.8
14.6
14.6
21.8
14.5
28.8
19.2
42.3
28.2
52.5
25.0
82.5
36.0
97.5
58.0
120
58.0
EDKVS9332X DE/EN/FR 4.0