EVS9330 ... EVS9332
(fold−out page on the right)
Position
Description
0
Controller
1
Fixing bracket for standard mounting
2
EMC shield sheet with fixing screws for shielded control cables
3
Cover with fixing screws
4
Shield clamp and strain relief for the motor cable
5
Strain relief for the PE motor cable and the feed cable for the motor temperature monitoring with PTC thermistor
or thermal contact (NC contact)

Connections and interfaces

Position
Description
L1, L2, L3, PE Mains connection
+UG, −UG
DC supply
U, V, W, PE
Motor connection
T1, T2
Connection of PTC thermistor or thermal contact (NC contact) of the motor
X1
AIF interface (automation interface)
Slot for communication module (e. g. XT EMZ9371BC keypad)
X3
Jumper for setting analog input signal at X6/1, X6/2
X4
System bus (CAN) connection
X5
Connection of digital inputs and outputs
X6
Connection of analog inputs and outputs
X7
Connection of resolver and KTY temperature sensor of the motor
X8
Connection of incremental encoder with TTL level or SinCos encoder and KTY temperature sensor
of the motor
X9
Connection of digital frequency input signal
X10
Connection of digital frequency output signal
X11
Connection of K

Status displays

Position
LED red

Off
On
Off
Blinking quickly
Blinking slowly
0Fig. 0Tab. 0
EDKVS9332X DE/EN/FR 4.0
relay output for "safe standstill" (for variants V004 and V104 only)
SR
LED green
On
On
Blinking slowly
Off
Off
Operating status
Controller enabled
Mains is switched on and automatic start is inhibited
Controller inhibited
Undervoltage or overvoltage
Active fault
l