5.8.5
Terminal assignment
Analog input configuration
Terminal
X6/1, X6/2
1)
Lenze setting (delivery state)
Non−configurable control terminals
Terminal
X11/K32
X11/K31
X11/33
X11/34
X5/28
X5/ST1
X5/ST2
Lenze setting of the configurable control connections for the 9300 Servo PLC
Terminal
X5/E1
X5/E2
X5/E3
X5/E4
X5/E5
X5/A1
X5/A2
X5/A3
X5/A4
X6/1, X6/2
X6/3, X6/4
X6/62
X6/63
EDKVS9332X DE/EN/FR 4.0
Jumper strip X3
Jumper setting
1)
1−2
6
5
4
3
3−4
2
1
5−6
Description
Function
Safety relay K
Pulse inhibit feedback
SR
1st disconnecting
path
– coil of safety relay K
+ coil of safety relay K
Controller inhibit
Controller enable/inhibit
(DCTRL−CINH)
2nd disconnecting
path
STATE−BUS
Description
Function
Digital inputs
Not assigned
Not assigned
Not assigned
Not assigned
Not assigned
Digital outputs
Not assigned
Not assigned
Not assigned
Not assigned
Analog inputs
Not assigned
Not assigned
Analog outputs
Not assigned
Not assigned
l
Electrical installation
Wiring of the control connections
Terminal assignment
SR
SR
5
Possible levels
1)
−10 V ... +10 V
−10 V ... +10 V
−20 mA ... +20 mA
Level / state
Open contact: pulse
inhibit is inactive
(operation)
Closed contact: pulse
inhibit is active
Coil is not carrying any
current: pulse inhibit is
active
Coil is carrying current:
pulse inhibit is inactive
(operation)
LOW: Controller
inhibited
HIGH: Controller enabled
Level
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
−10 V ... +10 V
−10 V ... +10 V
−10 V ... +10 V
−10 V ... +10 V
191