ENGLISH
CAUTION! Danger of material damage!
Improper transport or temporary storage can result in
damage to the product.
•Always transport the pump with care.
•Drain the pump prior to storage.
•Store the pump somewhere dry and frost-free.
•Observe the operating instructions of the combustion
engine.
Draining the pump for temporary storage
•Switch off the pump and secure it against being switched
back on again.
•Open the access/drain opening and drain the water entirely.
•Close the access/drain opening again.
4. INTENDED USE
The pumps of the TP 2800 series are for pumping wastewater
with a low proportion of solid particles. Areas of application:
•Draining excavation ditches
•Draining ponds
•Pumping out seepage water
•Spraying/irrigation of gardens and lawns
WARNING! Danger of suffocation!
The exhaust fumes of combustion engines are toxic.
There is a danger of suffocation if they are inhaled. Only
use pumps with combustion engines outdoors, never
indoors!
5.2 Technical Data
Pump
Suction port / discharge port
Max. grain size
Housing material
Impeller material
Material of mechanical seal
Material of static seal
Electric motor
Rated motor power P
2
Rated current
Frequency
Winding
Speed
Insulating material class
Protection class
Operating mode
Cooling
Four-stroke combustion engine
Engine power
Cubic capacity
Fuel type
Tank capacity
No-load speed
Cooling
Starter
TP 2802
G 1 1/2" (DN40)
< 4 mm
Cast aluminium
EN-GJL-250
Carbon / aluminium oxide
NBR
See data plate
See data plate
50 Hz
Three-phase current 230 - 400 V
2900 rpm
F
IP55
S1
Air cooling
TP 2802
2.21 kW / 3 PS
3
127 cm
See the operating instructions for the combustion engine
2.8 l
3600 rpm
Air cooling
Manual, pull starter
11
WARNING! Health hazard!
Due to the materials used, the pump is not suitable for
pumping drinking water! Contamination with wastewa-
ter poses a health hazard. Do not use pumps for drink-
ing water!
CAUTION! Danger of material damage!
Pumping impermissible substances can damage the
product. Never pump water containing salt or chlorine
and never pump substances such as rough paper, rub-
ble, waste, animal waste, long-fibred material or swim-
ming pool water!
Proper use includes following these instructions.
Any other use is considered improper.
5. PRODUCT DETAILS
5.1 Type key
Example:
TP 2802 TR
TP 28
Serial designation
02
Size designation
T
Three-phase current
R
Version with trolley
Example:
TP 2802 ER
TP 28
Serial designation
02
Size designation
T
Four-stroke combustion engine (petrol)
R
Version with trolley
TP 2810
G 2" (DN50)
< 4 mm
Grey cast iron EN-GJL-250
EN-GJL-250
Carbon / aluminium oxide
NBR
TP 2810
3.68 kW / 5 PS
205 cm
TP 2820
G 3" (DN80)
< 4 mm
Grey cast iron EN-GJL-250
EN-GJL-250
SiC / SiC
NBR
3