Menu Installer Settings - Anselmo Cola TERMOPLUS 23 Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

-Occurs in case of water T
detection probe
Al C
fault,
WATER PROBE
displaying T H2O = 0 °C.
S1
- The shutdown procedure
is activated.
-Occurs when the water
AL F
temperature has exceeded the
HOT
fixed limits.
WATER S1
-The system is stopped.
-Occurs in case of water T
detection probe
Al G
fault,
WATER PROBE
displaying T H2O = 0 °C.
S2
- The shutdown procedure
is activated.
-Occurs when the water
AL I
temperature has exceeded the
HOT
fixed limits.
WATER S2
-The system is stopped.
-Occurs in case of water T
detection probe
Al H
fault,
WATER PROBE
displaying T H2O = 0 °C.
S3
- The shutdown procedure
is activated.
-Occurs when the water
AL d
temperature has exceeded the
HOT
fixed limits.
WATER S3
-The system is stopped.
-Occurs on relighting the stove
AWAITING
immediately after having shut it
COOL
down.
AIRFLOW
-Occurs when the air flow meter is
METER
disconnected.
FAILURE
-Occurs when the water
FROST RISK
temperature falls below a certain
value.
-Occurs when the stove has
exceeded 1800 hours of
SERVICE
operation or 2000 Kg pellet,
DUE
since the previous servicing.
8 INSTALLER

8.1 Menu installer settings

The following instructions are intended only for technical personnel specialised in heating units manufactured by
COLA.
Changing the parameters in a non-appropriate way can cause serious damage to people, the
units and the environment. In this case, Cola s.r.l. declines any liability.
To access the INSTALLER SETTINGS menu, press button P3 - MENU and use the scroll buttons to display the item
INSTALLER SETTINGS and then press button P3 - MENU. Use the scroll buttons to display access key 10 and
press button P3 - MENU.again.
The various parameters can be displayed with the scroll buttons; access with button P3 - MENU, edit them with the
scroll buttons and exit with ESC.
-Faulty probe
-The probe is disconnected from
the board.
-Occurs when the temperature
probe in the heating chamber
detects a value above 92°C.
-Faulty probe
-The probe is disconnected from
the board.
-Occurs when the temperature
probe in the heating chamber
detects a value above 92°C.
-Faulty probe
-The probe is disconnected from
the board.
-Occurs when the temperature
probe in the heating chamber
detects a value above 92°C.
-Reset attempt in shutdown stage
with stove hot in cooling stage.
-The controller does not detect
the amount of combustion air and
does not shut down the stove; it
only excludes the air flow meter
functions.
-The stove controller detects the
water temperature below 6°C
and displays a message.
-Extraordinary
maintenance
notice.
56
-Reinstatement operations must
be carried out by a service centre.
-Check the cause of the problem,
restoring the temperature by
bringing it to the normal operating
value.
-Reinstatement operations must
be carried out by a service centre.
-Check the cause of the problem,
restoring the temperature by
bringing it to the normal operating
value.
-Reinstatement operations must
be carried out by a service centre.
-Check the cause of the problem,
restoring the temperature by
bringing it to the normal operating
value.
-Alarm reset is possible only after
shutdown.
-Reinstatement operations must
be carried out by a service
centre.
-The pump starts in order to move
the water inside the heating
circuit.
- Monitor the water temperature
so that it does not fall below 0°C.
- Cleaning - extraordinary
maintenance and reinstatement
operations must be carried out by
an authorised service centre.
TERMOPLUS 23