Given below are the control and/or maintenance operations for correct stove use and operation.
Parts / Period
Type of cleaning
Brazier
Ash compartment-pan
Door glass
Heating chamber tube bundle
Manifold – fume extractor
Glass - door seal
Pipe - flue connection
5.1 Cleaning the brazier
Remove the brazier and the ash deposited in the combustion chamber and brazier holder. A suitable vacuum cleaner
may be used for this purpose. This operation must be carried out daily, especially in case of accumulated unburnt
matter, to ensure perfect combustion conditions, since the brazier holes allow the flow of combustion air.
Brazier dirty
5.2 Cleaning the ash container
The ash container is located directly under the brazier - brazier holder. To clean it, open the fire door and remove the
ash and any combustion residuals using a suitable vacuum cleaner.
Close the door after cleaning. The ash container can be cleaned every 2-3 days depending on stove use.
5.3 Cleaning the glass
The glass can be cleaned using a damp cloth and specific non-abrasive detergents.
Special slots between the glass, glass stops and fire door at the top and bottom allow air to circulate on the inside
surface of the glass. These slots must be kept clean of any deposits of ash and dust. Therefore periodically clean all
around the glass, on the inside and outside of the door.
5.4 Cleaning the fume extractor and combustion chamber
The combustion chamber must be cleaned at least once a year, removing all combustion residuals from the internal
fume pipes and flueways. To carry out this operation, it is necessary to remove the stove top cover, the heating
chamber cover and the bottom inspection door, undoing the relevant fixing screws, then clean the turbulators and
internal fume pipes.
Also, make sure to clean the fume extractor located under the bottom fume manifold accessed through the inspection
door opening.
Every 3-4 months clean the inside walls (insulating-refractory) of the combustion chamber using suitable equipment
(brushes) and replace the vermiculite wall if necessary.
Every 1800 hours of operation or 2000 Kg pellet, by means of a message 'SERVICE DUE', the stove signals the
need for extraordinary maintenance (not under warranty) to be performed by qualified personnel who will carry out
complete cleaning and reset the message.
Any knocking or forcing can damage the fume extractor, making it noisy during
operation; therefore it is advisable to have this operation carried out by qualified personnel.
5.5 Cleaning the air flow meter
The air flow meter (it measures the flow of combustion air) installed inside the inlet pipe requires periodical internal
cleaning every 3-4 months, using suitable equipment (blowing compressed air or suitable brushes).
5.6 Cleaning the ceramic surfaces
The ceramic tiles are handicraft products and therefore may have minor surface imperfections such as tiny spots or
slight colour differences. It is advisable to use a soft dry cloth to clean the ceramic surfaces; the use of detergents
could highlight any flaws.
1 day
2-3 days
routine
cleaning
■
Brazier clean
Brazier Holder clean
1 month
routine
routine
cleaning
cleaning
■
■
■
51
2-3
1 year
months
extraordinary cleaning:
carried out by the Service
routine
Centre
cleaning
■
■
■
■
■
The brazier must rest on the
brazier holder and precisely on
the entire ring band without air
gaps.
TERMOPLUS 23