-Occurs if the fume probe
detects a fume temperature
AL 3
above 280°C.
HOT FUMES
-The shutdown procedure is
activated.
-Occurs when the exhaust fan
AL 4
is faulty.
-The shutdown procedure is
FAN FAIL
activated.
-No flame in ignition stage.
AL 5
-The shutdown procedure is
NO IGNITION
activated.
AL 6
-Brazier not fed with pellets.
NO PELLETS
-Occurs in case of cutting in of
AL 7
auger duct temperature or
THERMAL
heating chamber water
temperature safety thermostat.
SAF
-The system is stopped.
Signalling
-In the work stage the stove
AL 8
detects a pressure below the
NO NEG
vacuum switch setting threshold.
PRESS
-The system is stopped.
AL 9
-Appears when the combustion air
INSUFF
flow is below a certain threshold.
DRAUGHT
-Occurs when the water pressure
AL E
does not come within the values
WATER
for correct operation.
PRESSURE
-The system is stopped.
-Occurs in case of cutting in
AL A
heating chamber water
temperature safety thermostat.
SAFETY H2O
-The system is stopped.
-Occurs when the gearmotor
AL B
works continuously and for more
AUG TRIAC
than 60 sec.
ERROR
-The system is stopped.
-Faulty tangential fan.
-No power to tangential fan.
-Too many pellets.
-The fume fan is blocked.
-Faulty speed control sensor.
-No power to fume fan.
-The pellet hopper is empty.
-The electrical element is faulty,
dirty or not correctly positioned.
-Pellet load setting incorrect.
-The pellet hopper is empty.
-The pellet feed gearmotor has
to adjust.
-The gearmotor does not feed
pellets.
-The safety thermostat has
detected a temperature above
the setting threshold due to
overheating of the bottom part
of the hopper or the heating
chamber water, blocking
gearmotor operation.
Fault
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty vacuum switch.
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty air flow meter.
-Occurs when the pressure
transducer on the water circuit
detects a pressure below or
above the fixed limits.
-The
detected a temperature above
the setting threshold due to
overheating
chamber
gearmotor operation.
-The controller detects a faulty
gearmotor control relay (contacts
stuck).
55
Possible causes
safety
thermostat
has
of
the
heating
water
blocking
-Adjust the pellet flow.
-Other reinstatement
operations must be carried out
by a service centre.
-Reinstatement operations
must be carried out by a
service centre.
-Check pellets in hopper.
-Check the lighting
procedures.
-Other reinstatement
operations must be carried
out by a service centre.
-Check pellets in hopper.
-Adjust the pellet flow
-Other reinstatement
operations must be carried
out by a service centre.
-Check the cause of excessive
overheating.
-Reset the relevant safety
thermostat by pressing the
reset button.
Cures
-Check cleanness of the fume
duct and combustion chamber.
-Check hermetic closing of the
door.
-Check closing of the
overpressure valves.
-Other reinstatement operations
must be carried out by a service
-Check cleanness of the fume
centre.
duct and combustion chamber.
-Check hermetic closing of the
door.
-Check
closing
of
overpressure valves.
-Other reinstatement operations
-Check the cause of the problem,
must be carried out by a service
restoring the circuit pressure by
centre.
bringing it to the normal operating
value.
-Check the cause of excessive
overheating.
-Reset the relevant safety
thermostat by pressing the reset
button.
-Reinstatement operations must
be carried out by a service centre.