Signalling
Occurs when the air flow
AIR FLOW
meter is disconnected. The
METER
control does not detect the
amount of combustion air and
FAILURE
does not shut down the stove
-Occurs when the stove has
exceeded 1800 hours of
SERVICE
operation or 2000 Kg pellet,
DUE
since the previous servicing.
8
INSTALLER
8.1
Menu installer settings
The following instructions are intended only for technical personnel specialised in heating units manufactured by
COLA.
Changing the parameters in a non-appropriate way can cause serious damage to people, the
To access the INSTALLER SETTINGS menu, press button P3 - MENU and use the scroll buttons to display the
item INSTALLER SETTINGS and then press button P3 - MENU. Use the scroll buttons to display access key 10
and press button P3 - MENU.again.
The various parameters can be displayed with the scroll buttons; access with button P3 - MENU, edit them with the
scroll buttons and exit with ESC.
It contains the adjustment parameters given below.
Parameter code
10-01
10-02
10-03
10-04
10-05
10-06
10-07
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
COLA S.r.l. – Viale del Lavoro, 7/9 – 37040 Arcole (VR) Italy – Tel. 045 7635780 – 045 6144043 – Cod. Fisc. – P.IVA e Iscr. Reg. Impr. 02990180230
Capitale Sociale Euro 52.000,00 i.v. – R.E.A. VR-301021 – Socio Unico – Fax Amministrazione 045 6100317 – Fax Commerciale 045 7639032
Fax Assistenza 045 7639030 – Fax Logistica 045 6144048 – e-mail: info@anselmocola.com – website: www.colastufe.com
ALARMS - MESSAGES
Fault
units and the environment. In this case, Cola s.r.l. declines any liability.
For increasing or decreasing auger OFF duration for all powers.
For increasing or decreasing fume extractor speed for all powers, by a
value of 5% for each unit.
Enable key lock.
Adjustment probe temperature setting ON/OFF delta (see parameter
10-07)
Stove shutdown delay.
Valid only in case of Standby set to ON.
For enabling self-calibration.
For selecting the probe on which stove adjustment is to be set:
- LOCAL PROBE: probe on stove and connected to the mainboard.
- RADIO PROBE: probe located on the radio remote control.
Direzione e coordinamento della Ferroli S.p.A.
Possible causes
The air flow meter connection
cable has been disconnected
The stove requires
extraordinary maintenance
Description
48
Cures
The stove continues its normal
operation and safety is
guaranteed by the remaining
devices. It is advisable to
contact a service centre
as soon as possible
The stove continues its normal
operation. It is advisable to
contact a service centre
as soon as possible
CLUB ERMETICA