- At first startup, remove all the components that could burn (instructions/label) from the stove firebox.
- Any lighting done after long idle periods requires the removal of any residual pellets that have remained
inside the hopper, in being damp fuel no longer suitable for combustion, and complete cleaning of the
combustion chamber.

4.3.2 Startup stage

To light the stove, press the button 'P4' for 3 seconds: the message 'START' will appear on the display.
This stage is automatic and managed entirely by the electronic controller without the possibility of changing the
parameters.Alternatively the stove can be lit by pressing the buttons P4 and P5 together for 3 seconds. The message
AWAITING REQUEST appears on the display. With this mode the stove switches to standby status and carries out
the lighting-start stage only if a request for heat is recognised, e.g. to heat the water or for DHW (if available).
Dialogue box
The stove carries out the startup stages in sequence
according
to the
procedures defined
parameters that manage levels and times, reaching
the work condition unless anomalies or alarms occur,
according to the following table:
After a certain time has elapsed, if the fume
temperature has not reached the permissible
minimum value the stove goes in alarm status.
- Do not use flammable liquids to light the unit.
- In case of persistent failed lighting, contact the Service Centre.

4.4 Work stage

After the 'STARTUP' stage, the stove goes to the 'WORK' mode which is the normal operation mode.
The user can adjust the heating power from the max. value of 5 to a min. of 1 with the buttons 'P5' and 'P6'.
DHW circuit function activation ON is displayed by the segment/LED [A].
Storage tank -Puffer
H20 temperature or
'ROOM' word
Dialogue box
Power set to
Clock
Storage tank-Puffer H
Water temperature
by the
Clock
3
0 temperature
2
Button 'P4'
Status
OFF
START - PREHEAT
PELLET PRELOAD
AWAITING FLAME
PELLET LOADING
FIRE PRESENT
WORK
WORK MODULATE
BRAZIER CLEANING
WORK
FINAL CLEANING
A
Button 'P6'
Button 'P5'
Water temperature or room temperature
Real power in work equal to 1 - flashing
44
Devices
Fume
igniter
auger
extr.
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
TERMOPLUS 23
exch.
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
-

Publicité