2) SCALE CONFIGURATION
ENTERING THE MENU
Press
twice to enter the Password mode.
The Scale displays
. Input the Scale Configuration password. To do so,
press
or
, then
, to modify the digital. Press
move the digital.
Press
, to confirm input and enter the Scale Configuration.
Scale displays
Press
to enter the Auto-Zero range setting.
AUTO-ZERO-RANGE
The scale displays the Auto-Zero range, e.g.
boot-up, the scale automatically zeroes. The Auto-Zero range can be set to:
0%(disabled), 2%, 3%, 4%, 10%, 20%, 100% F.S..
Press
Or
, and
to change the Auto-Zero range.
Press
to exit and save.
Press
or
to exit without saving.
Press
, to enter the manual-Zero range setting.
EN
MANUAL ZERO RANGE
The scale displays the Manual-Zero range, e.g.
is only allowed when the weight is within the Manual-Zero range, which can be
set to : 0%(disabled), 2%, 3%, 4%, 10%, 20%, 100% F.S..
Press
or
, and
Press
to exit and save. Press
Press
, to enter the Zero-Tracking range setting.
ZERO TRACKING RANGE
The scale displays the Zero-Tracking range, e.g.
Tracking range, which can be set to: 0(disabled), 0.5e, 1.0e, 1.5e, 2.0e, 2.5e,
3.0e, 4.0e, 5.0e. Enabling the Zero-Tracking will enhance the scale temperature
and drift the performance!
Press
or
, and
Press
to exit and save. Press
Press
to enter the Gravity setting.
or
.
, indicating 20% F.S.. Upon
, indicating 4% F.S.. Zero
to change the Manual-Zero range.
or
to exit without saving.
, indicating 0.5e. Zero-
to change the Zero-Tracking range.
or
to exit without saving.
35
GRAVITY
The scale displays the Gravity, e.g.
be set from 9.700 to 9.899. Only adjust the Gravity when scale is used in a place
where the acceleration of gravity is greatly different from the place where it was
calibrated.
Press
, and
, to
and
Press
Press
USER UNIT
The scale displays the User Unit, e.g.
set to 1.000. The User Unit can be set from 0.000 to 9.999.
The User Unit is a named unit which is usually used in the user's region, but
which is not included in the scale by default. It is a ratio to the System Unit. For
example, if the User Unit is set to 1.234 and if the System Unit is kg, then after
switching to User Unit, the scale measures the weight (1000kg), and displays the
calculated value (1234usr).
This means you have to watch up the maximal load hanging on the scale while
using the user unit, to not overload the scale because of a different displayed
value!
Press
to move the digital. Input the User Unit.
Press
Press
Rev. II.2017
Rev. II.2017
, indicating g is 9.794. This value can
or
, and then
to modify the digital. Press
to move the digital. Input the Gravity value.
to exit and save. Press
or
to enter the User Unit setting.
, , indicating that the user unit is
or
, and
to modify a digital. Press
to exit and save. Press
or
to go back to Auto-Zero.
36
or
to exit without saving.
EN
or
, and
,
to exit without saving.