6.3 Hydraulic system
Connection to the hydraulic system and
the system itself must be performed
by qualified personnel, in compliance
with the laws and regulations in force
in the country of installation.
Make sure that all the control and
safety devices have been installed
correctly, including those supplied
(safety valves and thermal discharge).
The system must be designed in such
a way as to absorb the minimum
power of the stove in any operating
condition.
To easily intervene on the hydraulic
system proceed as follows:
• Open the door, loosen the fixing screws
of the front panel (1) and remove it
(Fig. 6.3a), to access the vent valve.
• Loosen the two front screws (2), loosen
the four rear fixing screws of the right
side (3) and remove it (Fig. 6.3b - 6.3c).
1
2
2
Fig. 6.3b
004778021 - 08/04/2021
Fig. 6.3a
3
3
3
3
Fig. 6.3c
53