6.7 LEVELLING THE STOVE

in compliance with EN 10683.(Fig. 6.7)

6.8 SYSTEM CONNECTIONS

6.8.1 Electrical connection

The stove is connected to the electrical system
simply using the plug supplied.
The electrical connection (plug) must be easily
accessible when the stove is installed.
If the power cord is damaged it must be replaced
prevent any kind of risk.
6.8.1.1 Earth
The system must be earthed and fitted with a
legislation in force (Fig. 6.8.1).
6.8.2 Connection to an external timer thermostat
(Fig. 6.8.2) The stove can be connected to an
external timer thermostat that switches the stove
on or off according to the set temperature.
When the set temperature is reached the
thermostat opens the circuit and consequently
switches off the stove.
The external thermostat is connected to the two
terminals on the board of the stove, which are
jumpered in the factory. Disconnect the jumper
and connect the two thermostat contacts.
the instructions shown in the paragraph on "Initial
needs to be switched on manually, while the timer
thermostat is in "call" status. This operation is also
required in the event of power failures or if the stove
is switched off manually.
To avoid overlapping the working time bands, it's
recommend to disable (set to OFF) the stove's timer
6.8.3 Connection to a room thermostat
room thermostat (normally in open position).
Near the electronic card there is terminal to which
the thermostat wires are to be connected
The section of the cable must be selected based
on its length.
The sheaths and the cables of external electrical
components must not touch hot parts or sharp
edges.