4.10 DEFAULT SETTINGS VALUES / VOREINGESTELLTE STANDARDWERTE
/ VALEURS PAR DÉFAUT DES PARAMÈTRES / VALORES DE CONFIGURACIÓN
POR DEFECTO / VALORI PREDEFINITI DI IMPOSTAZIONE
Label
Set point
Set
Differential
Hy
Minimum set point
LS
Maximum set point
US
Thermostat probe calibration
Ot
Evaporator probe presence
P2P
Evaporator probe calibration
OE
Third probe presence
P3P
Third probe calibration
O3
Fourth probe presence
P4P
Fourth probe calibration
O4
Outputs delay at start up
OdS
Anti short cycle delay
AC
P1-P2 percentage for regulation
rtr
Continuous cycle duration
CCt
Set point for continuous cycle
CCS
Compressor ON time with faulty probe
Con
Compressor OFF time with faulty probe
COF
Temperature measurement unit
CF
Resolution
Res
Probe displayed
Lod
Display temperature delay
dLy
P1-P2 percentage for display
dtr
Defrost type
tdF
Probe selection for defrost termination
dFP
Defrost termination temperature
dtE
Interval between defrost cycles
IdF
(Maximum) lenght for defrost
MdF
Start defrost delay
dSd
Displaying during defrost
dFd
MAX display delay after defrost
dAd
Drip time
Fdt
First defrost after start up
dPo
Defrost delay after fast freezing
dAF
Fan operating mode
Fnc
Fan delay after defrost
Fnd
Differential of temperature for forced
Fct
activation of fans
Fan stop temperature
Fst
Fan on time with compressor off
Fon
Fan off time with compressor off
FoF
Probe selection for fan management
FAP
Temperat. Alarms configuration
Alc
Maximum temperature alarm
ALU
Minimum temperature alarm
ALL
Rev. 00
Name
Use and maintenance manual
Range
LS÷US
0,1÷25,5°C/1÷255°F
-50°C÷SET/-58°F÷SET
SET÷110°C/SET÷230°F
-12÷12°C/-120÷120°F
n=not present; Y=pres.
-12÷12°C/-120÷120°F
n=not present; Y=pres.
-12÷12°C/-120÷120°F
n=not present; Y=pres.
-12÷12°C/-120÷120°F
0÷255 min
0÷50 min
0÷100 (100=P1, 0=P2)
0.0÷24.0 h
-55÷150,0°C/-67÷302°F
0÷255 min
0÷255 min
°C ÷ °F
in=integer;dE=dec.point
P1;P2
0÷20.0 min (10 s)
0÷99
EL=el.heater;in=hot gas
nP;P1;P2;P3;P4
-50÷50°C
1÷120 h
0÷255 min
0÷99 min
rt,it,Set, DEF
0÷255 min
0÷120 min
n=after IdF; y=immed.
0÷23h 50'
C-n;o-n,C-y; o-Y
0÷255 min
0÷50°C
-50÷50°C/ -58÷122°F
0÷15 min
0÷15 min
nP;P1;P2;P3;P4
rE=rel. to set; Ab=abs
Set÷110,0°C/Set÷230°F
-50°C÷Set/-58°F÷Set
Factory default
val.
Refriger. Freezer
4,5
-20
---
1
1
Pr1
2
-25
Pr2
16
-10
Pr2
0
0
Pr1
y
y
Pr1
0
0
Pr2
n
n
Pr2
0
0
Pr2
n
n
Pr2
0
0
Pr2
0
0
Pr2
1
1
Pr1
100
100
Pr2
0
0
Pr2
-2
-2
Pr2
0
0
Pr2
0
0
Pr2
°C
°C
Pr2
De
De
Pr1
P1
P1
Pr2
0
0
Pr2
50
50
Pr2
IN
IN
Pr1
P2
P2
Pr2
8
8
Pr1
10
6
Pr1
20
20
Pr1
0
0
Pr2
dEF
dEF
Pr2
20
20
Pr2
1
1
Pr2
N
N
Pr2
0
0
Pr2
o-n
o-n
Pr1
0
0
Pr1
3
3
Pr2
10
3
Pr1
0
0
Pr2
0
0
Pr2
P2
P2
Pr2
AB
AB
Pr2
10
-13
Pr1
-4
-27
Pr1
66