The keypad is available as accessory. A full description can be obtained from the information included
in the keypad delivery.

Menu structure

All parameters for controller setting or monitoring are saved in codes under the menus User and all.
The codes have numbers 6 and are abbreviated in the text with a "C" before the number. Some codes
store the parameters in numbered "Subcodes" 7 to provide a clear structure for parameter setting
(example: C0517 menu User).
The menu User
l
– is active after every mains switching or keypad attachment during operation.
– contains all codes for a standard application with linear V/f characteristic control (Lenze
setting).
– can be modified as required under C0517.
The menu all
l
– contains all codes.
– shows a list of all codes in ascending order.
The change between User and all and how to change parameters in the codes is described
l
on the following pages.