7
Commissioning
Parameter setting using the keypad
The menu U U U U s s s s e e e e r r r r - The 10 most important drive parameters
After mains switching or plugging in the keypad during operation, the 10 codes defined to be the most
important in the user menu User (Code C0517) are available immediately.
In default setting the menu contains User all codes required for a standard application with linear V/f
characteristic control.
Code
Name
C0050 Output frequency
C0034 Setpoint selection range
C0034 Setpoint selection range
C0007 Fixed configuration of digital
C0007 Fixed configuration of digital
inputs
inputs
C0010 Minimum output frequency
C0011 Maximum output frequency
C0012 Acceleration time main
setpoint
C0013 Deceleration time main
setpoint
C0015 V/f-rated frequency
C0016 U
boost
min
C0002 Parameter set transfer/reset
Tip!
Use C0002 "Parameter set transfer" to easily transfer configurations from one controller
to the other or to reset the controller to Lenze settings.
20
Lenze setting
Display: Output frequency without slip compensation
-0-
0
Standard-I/O
Application-I/O
-0-
0
E4
CW/CCW
CW/CCW
rotation
0.00 Hz
50.00 Hz
5.00 sec
5.00 sec
50.00 Hz
depending on the inverter type
see code table ( ¶ 31)
EDK82EV3 DE/EN/FR 2.0
X3/8:
0 ... 5 V / 0 ... 10 V / 0 ... 20 mA
X3/1U:
0 ... 5 V / 0 ... 10 V
X3/2U:
0 ... 5 V / 0 ... 10 V
E3
E2
DCB
JOG2/3
DC-injection
Selection of fixed setpoints
brake
E1
JOG1/3
L