Les langues disponibles

6.
sysTem descripTiOn
6.1.
general description
The direct-acting solenoid valve Type 6012 is available in
two designs.
Type 6012 is used for the blocking, dosing,
filling and venting of neutral gaseous and
liquid media, in particular for controlling
single-acting pneumatic drives or technical
vacuum. The modular designed valve can be
installed individually or in a block on the mul-
tiple manifold.
Type 6012P is used as a special pilot valve
for direct installation on the externally con-
trolled pneumatic drives. It consists of the
magnetic drive Type 6012 and a special
connection body with hollow screw which
can be connected directly to the control air
connection of the drive. The valve features
manual actuation as standard.
english
12
7.3.

mechanical data

Dimensions
See data sheet
Body material
Type 6012: Brass, polyamide (PA),
Type 6012P: Polyamide (PA)
Hollow screw
Type 6012P: Brass, nickel-plated
Sealing material
FKM / EPDM
7.4.

fluidic data

Circuit functions
2(A)
C
3/2-way valve, direct-acting,
(NC)
normal output A unloaded
1(P) 3(R)
2(B)
D
3/2-way valve, direct-acting,
(NO)
normal output B pressurized
1(P) 3(R)
Pressure range
0 – 16 bar
Line connectors
Type 6012: M5, G1/8, Flange
Type 6012P: G1/8, G1/4
Note the information specified on the label for
voltage, type of current, and pressure.
english
14
Stainless steel 1.4305
Hose connector ∅ 6 mm
7.

Technical daTa

7.1.

Operating conditions

Warning!
Risk of injury
Malfunction if used outside!
Do not use Type 6012 outdoors and avoid heat
sources which may cause the allowable temperature
range to be exceeded.
Ambient temperature:
-10 – +55 °C
Medium temperature:
-10 – +100 °C
Media:
neutral gaseous and liquid media
(e.g. compressed air, Water, Hydraulic
fluid, technical Vacuum)
Viscosity:
max. 21 mm²/s
Protection class: IP65 in accordance with EN 60529 with
cable plug
7.2.
conformity
CE mark conforms to EMC Directive 2004/108/EEC (pre-
viously: 89/336/EEC; only if cables, plugs and sockets
have been connected correctly).
7.5.
lable (example)
Body material
Sealing material
Orifice
Circuit function
Type
6012 C 1,2 FKM MS
G1/8 PN 0 - 10 bar
24V
00450000
Ident. no.
Voltage/Frequency output
Nominal connection pressure
Type 6012
english
13
13
50Hz
4W
CE
WXXXX
english