Monitoring of the Operation
Note:
The unit is not equipped with an ON/OFF switch and it must be
constantly connected to the power supply, also over weekends.
Disconnection is only permitted for maintenance purposes. When the
power supply is interrupted, the condensate drain issues an alarm
signal.
The condensate drain is a fully automated device. Its operation and status can be
monitored by observing the LED, so that disruptions and malfunctions are
immediately detected. The LED signals and their significance are listed in the
table below.
ED3002 - ED3004
LED
colour
green
green/
red
red
ED3007 - ED3100
LED
colour
green/
yellow/
red
green
orange
red
Ecodrain ED3002–ED3100_FR-EN_7
LED signal
flashing at short intervals for
3 seconds
flashing at long intervals
permanently on
flashing
flashing at long intervals
flashing at short intervals
LED signal
flashing
slowly flashing
permanently on
permanently on
flashing at long intervals
flashing at short intervals
permanently on
Description
System initialisation
Valve active, condensate is being
drained
Drain ready for operation
Warning signal (not an alarm signal):
No condensate drained off for 15 hours
Cleaning program activated
Emergency program activated (alarm)
Description
System initialisation
Valve active, condensate is being
drained
Drain ready for operation
Warning signal (not an alarm signal):
No condensate drained off for 15 hours
Cleaning program activated
Emergency program activated (alarm)
System error (alarm), drain defective
English