Operating Instructions - SKF TMJL 100 Mode D'emploi

Masquer les pouces Voir aussi pour TMJL 100:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19

3. Operating instructions

a) Check oil level by unthreading the container
plug on the rear end of the container.
Make sure there is enough of oil for your
complete operation. For mounting bearings with
the SKF Oil Injection Method, or by means of an
hydraulic nut, it is recommended to use an oil
with a viscosity of approximately 300 mm
(1 400 SUS) at the operating temperature.
For dismounting bearings, we recommend to
use an oil with a viscosity of approx 900 mm
(4 100 SUS) at operating temperature.
b) Hold the pump horizontally or slightly tilted
forwards in order to secure oil supply.
c)
Close the release valve on the right hand side of
the pump without using force.
A
A.
Oil release valve
B.
Handle block pin
C.
Pressure gauge
d) Screw the quick connection nipple (G
the application.
e) Connect the hose to the nipple by gently
withdrawing the snap-ring on the quick
connector. The hose is disconnected in the same
manner.
/s
f)
Continue pumping until necessary pressure is
2
reached for your application. Maximum pressure
is 100 MPa (14 500 psi) at which pressure the
/s
safety valve will open.
2
g) Open the release valve not more than one turn,
allowing superluous oil to return to the oil
container.
B
/
) into
1
4
C
EN
5

Publicité

Table des Matières
loading

Table des Matières