3. Operating instructions

a)
Check oil level by unthreading the container plug on top of the square container.
Make sure there is enough of oil for your complete operation. For mounting
bearings with the SKF Oil Injection Method, or by means of an hydraulic nut, it is
recommended to use an oil with a viscosity of approximately 300 mm
(1 400 SUS) at the operating temperature. For dismounting bearings, we
recommend to use an oil with a viscosity around 900 mm
operating temperature.
b) Hold the pump horizontally or slightly tilted forwards in order to secure oil supply.
c) Close the release valve on the right hand side of the pump without using force.
d) Screw the quick connection nipple (G 1/4) into the application.
e)
Connect the hose to the nipple by gently withdrawing the snap-ring on the quick
connector. The hose is disconnected in the same manner.
f)
Continue pumping until necessary pressure is reached for your application. Maximum
pressure is 50 MPa (7 250 psi) at which pressure the safety valve will open.
g)
Open the release valve, allowing superfluous oil to return to the oil container.
A
Filter plug
B
Handle block pin
C
Pressure gauge connection
D
Oil release valve
6
A
D
/s
2
/s (4 100 SUS) at
2
B
SKF TMJL 50
C

Publicité