4. Maintenance
4.1 Replacing the oil
When replacing the oil or after maintenance, make
sure no air is trapped in the system. This should be
checked before attaching the hose to the application
by making sure only air-free oil comes out of the
hose when pumping. Only use clean, recommended
hydraulic oils.
4.2 Cleanliness
Keep the pump clean from dirt and metal particles
in order to avoid excessive wear.
4.3 Replacement parts
Designation
TMJL 100–1
TMJL 100–2
TMJL 100–3
728245/3A
729831 A
729832 A
729834
1077587
THGD 100
TMJL 100–5
Items marked * are ONLY for TMJL 100DU.
4.4 Accessories
Designation
LHMF 300/5
LHDF 900/5
The contents of this publication are the copyright of the
publisher and may not be reproduced (even extracts) unless
prior written permission is granted. Every care has been
taken to ensure the accuracy of the information contained in
this publication but no liability can be accepted for any loss or
damage whether direct, indirect or consequential arising out of
the use of the information contained herein.
6
EN
Description
Hand-pump (sub-assembly)
Repair kit
Gauge connection nipple
Carrying case
Quick connection coupling, G
Quick connection nipple, G
High pressure hose
Pressure gauge (120 MPa, 100 mm)
Precision digital gauge*
Nipple for digital pressure gauge*
Description
Mounting luid (5 litre, 300 mm
Dismounting luid (5 litre, 900 mm
1
/
4
/
1
4
/s at 20 °C)
2
/s at 20 °C)
2