1. Description

The TMJL 100 has a maximum pressure of 100 MPa (14 500 psi) and delivers a volume
per stroke of 1 cm
(0.06 in
3
hydraulic pullers etc, but is also suitable for other oil injection applications where a
maximum pressure of 100 MPa (14 500 psi) is required. The pump is supplied with a
3 metre long, high pressure hose with quick connection coupling. Mating quick connection
nipple for attachment to the workpiece is included. The pump is filled with SKF mounting
fluid LHMF 300 and comes with an additional 1 litre can with the same fluid.
Everything is packed in a sturdy case. The pump has an over-pressure valve and a
pressure gauge. The release valve is an integrated part of the pump head.

2. Technical data

Maximum pressure
Volume per stroke
Oil container capacity
Handle force at 100 MPa
Pressure hose
Connection nipple
Oil viscosity of mounting fluid
Weight (filled with oil)
Designation

3. Operating instructions

a)
Check oil level by unthreading the container plug on the rear end of the container.
Make sure there is enough of oil for your complete operation. For mounting
bearings with the SKF Oil Injection Method, or by means of an hydraulic nut, it is
recommended to use an oil with a viscosity of approximately 300 mm
(1 400 SUS) at the operating temperature. For dismounting bearings, we
recommend to use an oil with a viscosity of approx 900 mm
operating temperature.
b)
Hold the pump horizontally or slightly tilted forwards in order to secure oil supply.
c)
Close the release valve on the right hand side of the pump without using force.
d)
Screw the quick connection nipple (G
e) Connect the hose to the nipple by gently withdrawing the snap-ring on the quick
connector. The hose is disconnected in the same manner.
f)
Continue pumping until necessary pressure is reached for your application. Maximum
pressure is 100 MPa (14 500 psi) at which pressure the safety valve will open.
g)
Open the release valve not more than one turn, allowing superfluous oil to return to
the oil container.
SKF TMJL 100
). It is mainly intended for use on HMV nuts, bolt tensioners,
3
100 MPa (14 500 psi)
1 cm
(0.06 in
3
800 cm
(49 in
3
320 N (70 lbf ft)
3 m (10 ft) long with quick connection coupling
G
/
, external or internal thread
1
4
300 mm
/s (1 400 SUS) at 20 °C
2
13 kg (29 lb)
TMJL 100
/
) into the application.
1
4
)
3
)
3
2
/s (4 100 SUS) at
2
/s
5

Publicité

Table des Matières
loading