Countertop
Mounting
Stud
(not supplied)
Mounting Nut
(not supplied)
Mounting
Bracket
Installing Bottom Mount units using optional Mounting Brackets
Remote Drain Handle
A remote drain handle option allows easy manual drain
valve shutoff. Use the following procedure to install a cabinet
mounted drain handle.
1. Mount the Drain Handle to the cabinet.
• Refer to the "Remote Drain Handle Enclosure Cutout
Dimensions" illustration for the appropriate cutout
dimensions.
• Drain handle must have a maximum 2" (51 mm) offset
from drain pipe.
• Distance from front of cabinet to center of drain must be
less than 26" (660 mm).
• Use the four screws to secure the Drain Handle
enclosure to the cabinet.
2. Remove the valve handle/knob by loosening nut.
• Units with Ball Valve: Save the nut for reuse, handle no
longer needed.
• Units with Gate Valve: Save the nut for reuse, knob no
longer needed.
3. Install the valve coupling in place of removed valve handle
or knob using the previously removed nut.
Remote
Drain Handle
Assembly
Handle
Coupling
Cabinet
Form No. HWBM-0518
Cotter Pin
Wall
Remote Drain Handle Installation (Cabinet Cutaway)
OPTIONS AND ACCESSORIES
5-13/16"
(147 mm)
Remote Drain Handle Enclosure Cutout Dimensions
4. Slide the square key rod through the handle coupling
(cotter pin hole end facing up).
5. Insert the cotter pin into the key rod inside the handle
coupling.
6. Slide the key clamp onto the key rods.
7. Slide the top key rod into the valve coupling.
• Units with Gate Valve: use two shim washers inside
coupling.
8. Insert the cotter pin into the key rod.
9. Center the key clamp on the overlapping key rods leaving a
1/8" (3 mm) gap for front to back play. Tighten both screws.
• The key rods can be installed at a 26" (660 mm)
maximum distance from the front of the cabinet to the
center of the drain.
10. Spread both cotter pin ends to secure the rods inside the
couplings.
Key
Clamp
Key
Rod
Washers
27
2"
7-1/2" *
(51 mm)
MAX
(190 mm)
5-1/4"
(133 mm)
4"
* Tolerance of
(102 mm)
+/- 1" (25 mm)
5-1/4" (133 mm)
Cotter Pin
Ball Valve
Coupling
Gate Valve
Coupling

Publicité