INSTALLATION
Installing Top Mount Unit into Non-Combustible
Countertop
WARNING
FIRE HAZARD: Unit must be installed using ribbon
putty gasket between unit and installation surface per
installation instructions (refer to Installation section of
this manual).
NOTE: Mounting flange kit is not required for installation into
non-combustible material.
NOTE: Cut the opening for both the unit and the control
enclosure before placing unit into the countertop
opening.
NOTE: Make sure the installation location provides enough
room for the remote control enclosure, electrical
connections, and plumbing connections.
1. Cut the appropriate opening in the countertop. Refer
to "Non-Combustible Countertop Cutout Chart" in this
section.
2. Cut the appropriate opening for the control enclosure.
Refer to "Control Enclosure Cutout Dimensions" in this
section.
3. Place ribbon putty gasket around the cutout edge of the
countertop. Make sure the ribbon putty gasket overhangs
the cutout edge or seal unit with silicone adhesive.
Ribbon Putty Gasket
Non-Combustible
Countertop
Installing Ribbon Putty Gasket
NOTE: A roll of ribbon putty gasket material is supplied with the
unit.
4. Place the unit into the countertop opening.
5. Using a screwdriver, rotate the unit's EZ locking tab
outward to secure the unit to the underside of the
countertop. Rotate as many tabs as needed to secure the
unit to the countertop.
Note: The Hatco EZ locking tabs work on countertops that
Cutout edge
of countertop.
6. Carefully trim and remove the excess ribbon putty material
18
Non-Combustible
Countertop
EZ Locking Tabs
have a maximum thickness of 3/16" (5 mm). For
countertops 3/16"–2" thick, use optional adapter
bracket P/N R04.42.194.00. Refer to the OPTIONS
AND ACCESSORIES section for more information.
Tighten bolt against
underside of
countertop
Adapter Bracket
Bolt (included with bracket)
Thick Countertop Adapter Bracket
from around the unit.
English
EZ Locking
Tab
Hook bracket
into slot in
EZ locking tab.
Form No. HWBM-0518