User's Responsibility For Ce Compliance; Specifications; Warnings - RAMSEY WINCH HD-P 42,2 Traduction Des Instructions Originales

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SPECIFICATIONS*

First Layer Line Pull
Noise Level ................. .................................
Ambient Temperature Range
Gear Reduction ..........................................
Weight (without rope)
LAYER OF ROPE
Line pull per layer
* Rope Capacity per Layer
* Line Speed at
* These specifications based on recommended wire rope of 11 mm (0.433") 1960
grade wire rope and a 408 cc (24.9 cu in) /Rev. motor.

WARNINGS:

THE USER SHALL ENSURE THAT THE OPERATING PERSONNEL ARE GIVEN THE NECESSARY
TRAINING.
THE OPERATOR SHALL ALWAYS WORK IN COMPLIANCE WITH THE OPERATING INSTRUCTIONS.
A MOTOR SPOOL (OPEN CENTER) DIRECTIONAL CONTROL VALVE IS REQUIRED FOR BRAKE
OPERATION.
CLUTCH MUST BE FULLY ENGAGED BEFORE STARTING THE WINCH.
DO NOT DISENGAGE CLUTCH UNDER LOAD.
STAY OUT FROM UNDER AND AWAY FROM RAISED LOADS.
STAND CLEAR OF ROPE WHILE PULLING. DO NOT TRY TO GUIDE ROPE.
DO NOT USE WINCH TO LIFT, SUPPORT, OR OTHERWISE TRANSPORT PERSONNEL.
A MINIMUM OF 2 WRAPS OF ROPE AROUND THE DRUM BARREL IS NECESSARY TO HOLD THE LOAD.
IN CAR CARRIER APPLICATIONS, AFTER PULLING VEHICLE ON CARRIER, BE SURE TO SECURE
VEHICLE TO CARRIER BED. DO NOT MAINTAIN LOAD ON WINCH ROPE WHILE TRANSPORTING
VEHICLE. DO NOT USE WINCH AS A TIEDOWN.
AVOID CONDITIONS WHERE LOAD SHIFTS OR JERKS OCCUR. EXCESSIVE "INCHING" SHALL BE
AVOIDED.

USER'S RESPONSIBILITY FOR CE COMPLIANCE

1. Use only a motor spool (open center) control valve Per Hydraulic System Requirements.
2. If a remote-operated winch control valve is used, refer to Hydraulic System Requirements for Emergency
Stop components to be installed.
3. Adjust system relief pressure per Hydraulic System Requirements
4. Mount winch per Winch Mounting Instructions.
5. Install 11 mm (.433 inch), grade 1960 wire rope. For STD drum, maximum rope length of 24 M (80 ft) for
three layers maximum. Attach rope to the drum per Rope Installation Instructions. Hook must have a safety
latch and a minimum breaking strength of 105,5 kN.
SPECIFICATIONS AND WARNINGS
................................. 42,2 kN (9480 lb)
STD DRUM
kN
lb
m
STD DRUM
ft
MPM
56,7 LPM
FPM
(15 GPM)
..................
..................
............ 39.5 kg
1
2
42,2
35,2
9,480
7,900
6
15
20
50
9,7
11,6
32
38
1
79 db
-28C to 60C
(-20F to 140F)
5:1:1
(87 lb)
3
30,2
6,700
24
80
13,4
44

Publicité

Table des Matières
loading

Table des Matières