LED:
green steady signal
Signal:
An action has been
Meaning:
completed successfully
LED:
red steady signal
Signal:
Error
Meaning:
3 seconds
3 seconds
Fig. 2
Bedroom
Children's room
Living room
Kitchen
Boiler /
utility room
Workshop
RM
Bedroom
RM
RM
Childrens
room
RM at least
(e.g. fan, ventilation...) or bathrooms
- Unit is suitable for kitchens, if false alarms due to
steam can be ruled out
- At the highest installation position on the ceiling in the
middle of the room (not on walls )
- Minimum distance of 50 cm from walls, furniture,
lamps
- Monitored area maximum 60 m
height of 6 m
- Distance between two devices maximum 15 m
- Corridor length maximum 7.5 m
- Not onto the ceiling beam for ceiling beams with a
height of >20 cm, but 1 device per intermediate space
up to a maximum of 36 m
- For ceiling beams with a height of <20 cm, a detector
at the centre of the room (also possible on ceiling
beam)
– 39 –
acc. DIN 14676)
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
Bath
Kitchen
RM
RM
Childrens
Living room
room
optimal
RM
with maximum ceiling
2
in surface area
2
GB