10 Care for and maintain the ED07 pressure
regulator
Servicing the ED07 pressure regulator
No special care is required for the ED07 pressure regulator.
Damage to components!
Solvents and aggressive detergents will destroy the surface, labeling and seals of
the device!
O Only clean the device using a slightly damp cloth. Only use water to do this
and, if necessary, a mild detergent.
Danger of burns caused by hot coils!
Touching the valve coils during operating may lead to burns.
O Let the device cool off before disassembling.
O Do not touch the device during operation.
O Check that all seals and plugs for the plug connections are firmly fitted so that no
humidity can penetrate the ED07 pressure regulator during cleaning.
Maintaining the ED07 pressure regulator
The ED07 pressure regulator is maintenance-free.
O However, the system-specific maintenance intervals must be observed.
Check the ED07 pressure regulator seals
The seals in the ED07 pressure regulator may age faster under aggressive ambient
conditions. Defective seals will lead to pneumatic leaks and non-compliance with the
IP65 protection class.
O Every now and then, check that the seals on the pressure regulator are in perfect
order.

11 If Malfunctions Occur

Malfunction
Possible cause
No output pressure
No power supply
present
No set point stipulated
No supply pressure
available
Outlet pressure too
Supply pressure too low
low
Outlet pressure less
Consumers that use a lot of
than the set point
air (>1300 h l/min) cause a
major drop of pressure in
the device.
Outlet pressure does
Housing ventilation port is
not correspond to the
closed
stipulated set point
Defective diaphragm in the
housing ventilation port
Air is audibly
Gasket is missing or
escaping
damaged
The ED07 pressure
regulator and base plate
are not sealed tight
ED07 pressure regulator is
not leak-tight
Replace pneumatic
connections on the base
plate
ED07 pressure regu-
End plate exhaust is closed Open the exhaust and
lator does not bleed
NOTICE
CAUTION
Remedy
Connect the power supply.
Check the polarity of the
power supply.
Switch on system
component.
Stipulate a set point.
Connect the supply
pressure.
Increase the supply
pressure.
Reduce air consumption
Use a device with a larger
nominal width (e.g. ED12)
Make sure that the housing
ventilation port is open
Exchange the ED07
pressure regulator
Check the gasket and
exchange if necessary
Tighten screws with 6 Nm
torque
Exchange the ED07
pressure regulator
Correctly replace pneumatic
connections on the base
plate (see „Attach base plate
pneumatic connections")
connect a silencer or a line
for restricted exhaust.

12 Technical Data

General data
Dimensions (width x height x depth) 254 mm x 100 mm x 43 mm
Weight
Operating temperature range
Storage temperature range
control
Version
Permissible medium
Protection class according
to EN 60529/IEC529
Mounting orientation
Pneumatics
Flow rate at pre-pressure 7 bar
(101.5 psi), rated pressure 6 bar
(87 psi) and pressure drop 0.2 bar
(2.9 psi)
Supply pressure
Reproducibility
Hysteresis
Electronics
Supply voltage
Permissible harmonic content
Power consumption
Input current resistance (set point)
Current output (actual value),
external working resistance
1.8 kg
5 °C...50 °C
-20 °C...80 °C
Analog
Poppet valve
Air of quality class DIN ISO 8573-1
for solid impurities:
5 μm
for water content:
3
for total oil content:
1
IP65
(only when assembled and with all plugs
assembled)
preferred mounting orientation: vertical
(see figure 3)
Any if used with dry and oil-free
compressed air
The housing ventilation port must be open
1300 l/min
Supply pressure
Output pressure
Max. 0.12 bar
at 0...0.05 bar (0... 0.73
(1.74 psi)
psi)
Max.°0.7°bar
at 0...0.4 bar
(10°psi)
(0...5.8°psi)
Max.°3°bar
at -1...1 bar
(43.5°psi)
(-14.5... 14.5 psi)
Max.°8°bar
at 0...6 bar
(116°psi)
(0...87 psi)
Max. 12°bar
at 0...10 bar
(174°psi)
(0...145 psi)
Max. 18°bar
at 0...16 bar
(261°psi)
(0...232 psi)
Max. 21°bar
at 0...20 bar
(304.5°psi)
(0...290 psi)
Reproducibility
Output pressure
0.01 bar
at 6/10 bar
(0.15 psi)
(87/145 psi)
0.005 bar
at -1...1 bar
(0.073 psi)
(-14.5... 14.5°psi)
0.03 bar
at 16/20 bar
(0.435 psi)
(232/290 psi)
Hysteresis
Output pressure
0.03 bar
at 6/10 bar
(0.44 psi)
(87/145 psi)
0.015 bar
at -1...1 bar
(0.218°psi)
(-14.5... 14.5°psi)
0.09 bar
at 16/20 bar
(1.31 psi)
(232/290 psi)
24 V DC (+30%/-20%)
Only use a power pack with safe isolation for
the power supply
5%
Max. 1.4 A
Supply voltage switched on: 100 W
Supply voltage switched off: high-ohmic
< 300 Ω