6. Operation
When delivered the unit is pre-set for use. For the
Inspexx SD this means that the tank will be automati-
cally refilled and that the pump will start up when flow
appears in one or more outlets. Further, the pump will
stop when the flow ends.
Via a signal from a pressure sensitive switch the
pumps starts up and stops running via a signal from a
flow switch. The pressure sensitive switch is pre-set
by the supplier. The flow switch might have to be fine
tuned.
The adjustment of the flow switch is carried out as fol-
lows: open up one outlet, adjust the flow switch screw
until one yellow diode and one green diode lights up.
This must correspond the min. achievable consump-
tion.
Concentration of detergent is to be adjusted directly
on the inlet of the dosing pump. For further data and
service on the dosing pump please see data sheet
and manual for the dosing pump.
6.1. Daily operation
When adjusted according to the above descriptions
the unit runs automatically. This means that the tank
automatically is refilled and that the pump, during flow
in one or more outlets, is in operation.
Before using the outlet always connect a disinfection
nozzle or foam nozzle to the pistol/closing valve.
Only seconds after opening of the pistol/low pres-
sure valve the pump starts up and a working pressure
automatically appears.
7. Safety Instructions
Repairs must only be carried out when the water sup-
ply has been disconnected.
Attention:
Maintenance is only to be carried out
be authorized personnel.
12
8. Installation
8.1. Mounting of Inspexx SD
Attention:
a) The unit should be mounted in frost free rooms only.
b) The unit is leveled by adjusting the feet. When the
unit is leveled the lock nuts on the feet are to be tight-
ened thoroughly.
c) The unit is fastened to the floor using a bolt through
the hole on each foot. It is sufficient to fasten the feet
in the corners.
d) Always use a forklift
9. Settings
9.1. Setting before use
When delivered the unit is pre-set for use. For the
Inspexx SD this means that the tank will be automati-
cally refilled and that the pump will start up when flow
appears in one or more outlets. Further, the pump will
stop when the flow ends.
Via a signal from a pressure sensitive switch the
pumps starts up and stops running via a signal from a
flow switch. The pressure sensitive switch is pre-set
by the supplier. The flow switch might have to be fine
tuned.
The adjustment of the flow switch is carried out as fol-
lows: open up one outlet, adjust the flow switch screw
until one yellow diode and one green diode lights up.
This must correspond the min. achievable consump-
tion.
Concentration of detergent is to be adjusted directly
on the inlet of the dosing pump. For further data and
service on the dosing pump please see data sheet
and manual for the dosing pump.
9.2. Daily operation
When adjusted according to the above descriptions
the unit runs automatically. This means that the tank
automatically is refilled and that the pump, during flow
in one or more outlets, is in operation.
Before using the outlet always connect a disinfection
nozzle or foam nozzle to the pistol/closing valve.
Only seconds after opening of the pistol/low pres-
sure valve the pump starts up and a working pressure
automatically appears.