Technical Data
HxBxL
Weight
Inlet
Collection in container
Hose length rek. max.
Flow, max
Suction hose diameter
Neg. pressure, 230 V
Power consumption, 230 V
Fine fi lter polyester, area
Degree of separation
(EN 60335-2-69, Klass M)
Microfi lter area
Degree of separation
microfi lter
(EN 1822-1)
(EN 60335-2-69, Klass H)
Soundlevel */
*/ Sound level at 1,6 m height and 1 m distance according to
DIN EN ISO 3744 in free space and at maximum airfl ow.
Machine for the vacuuming and removal
of dry, health-hazardous, non-fl ammable
Class H dusts. Includes Demolition, Reno-
vation & Maintenance Work under German
Technical Rules for Hazardous Substances
TRGS 519.
The sample unit, when used for the intended
purpose, is thus suitable for the separation of
dry, health-hazardous, non-fl ammable, con-
ductive dust of all exposure limit values (dusts
with ELVs and dusts of carcinogenic substanc-
es as per the German Hazardous Substances
Ordinance (GefStoffV).
Information, instructions and training in the use
of the dust extraction machine and the dusts to
be separated should be obtained before use.
This machine is intended for commercial use
only, for example in hotels, schools, hospitals,
factories,shops, offi ces and rental businesses.
DC 1800 H
740x380x380 mm
10 kg
Ø 50 mm
15 l
5 m
200 m
/h
3
Ø 38
25 kPa
1285 W
1.5 m
2
99.9 %
0.85 m
2
99.9%
HEPA H13
99,995 %
70 dB(A)
Vacuum producer capacity
kPa
25
20
15
10
5
DC 1800/2800 H - 12
DC 2800 H
1100 x 440 x 550 mm
19 kg
Ø 50 mm
40 l
5 m
200 m³/h
Ø 38
25 kPa
1285 W
1.5 m²
99.9 %
0.85 m²
HEPA H13
99,995 %
70 dB(A)
50
100
150
3
200
m
/h