Technical Data
Description
TPR 35
Motor
kW
11
Pump RPM
rpm
3500
Weight
kg
400
Max dP
kPa
22
Nom. Pressure
kPa
20
Max Q
m
3
/h
1000
Sound Level of
Unit 1m
dB(A)
66
Inlet/Outlet
Ømm 160/160 160/160 160/160 108/108 160/160 108/108 160/160 108/108
POWER RATING
Hz
TPR 35
V
11 kW
220-240/
380-420
50
-
380-420/
660
50
106600
500
50
-
575
60
-
220/440
60
-
CAPACITY AND POWER CONSUMPTION
kPa
Pu
6 0
6
50
8
40
4
3
30
2
20
1 0
0
200
400
600
800
6
10
4
2 0
8
30
kW
P
1.
TPR 35 11 kW
2.
TPR 40 15 kW
3.
TPR 43 18,5 kW
4.
TSR 43 18,5 kW
5.
TPR 47 22 kW
6.
TSR 47 22 kW
7.
TPR 50 30 kW
8.
TSR 50 30 kW
The capacity curves for Dustcontrol vacuum producers
have been measured and are stated empirically. Outlet
pressure losses from a normal outlet (silencer, back-
fl ow valve/bend) have been accounted for in the curve.
Additional equipment such as a diffuser can result
in increased pressure loss and must be taken into
consideration.
TPR 40
TPR 43
TSR 43
TPR 47
15
18,5
18,5
22
4000
4300
4300
4700
400
430
430
450
26
28
46
29
22
22
35
23
1200
1400
650
1500
66
66
66
66
TPR 40
TPR 43
TSR 43
15 kW
18.5 kW
18.5 kW
106802
107202
107252
106800
107200
107250
106801
107201
107251
106806
107206
107256
106804
107204
107254
7
5
1
Q
m
1000
1200
1400
1600
1
2
3
5
7
TPR 35, 11 kW - 13
TSR 47
TPR 50
TSR 50
22
30
30
4700
5000
5000
450
530
530
50
30
54
37
25
40
700
1600
800
66
66
66
TPR 47
TSR 47
TPR 50
22 kW
22 kW
30 kW
107702 107752 109202 109252
107700 107750 109200 109250
107701 107751 109201 109251
107706 107756 109206 109256
107704 107754 109204 109254
TPR 35, TPR 40, TPR 43, TPR 47, TPR 50
3
/h
Stated air-fl ows are for standard air (101.3 kPa@ 20
C). The stated curves are for negative application,
all pressures stated are assumed to be below relative
atmospheric pressure at sea level. These devices can
also be used for positive pressure application and will
generate a greater pressure diff erential.
TSR 50
30 kW
Part No.
o
Art nr 9063