Technical Data
HxWxL
Weight
Inlet
Collecting sack 50 l
Hose length (φ 50)
Flow, max
Neg. pressure, max
Power consumption
Fine fi lter polyester, area
Degree of separation
(DIN 24184/3)
Filter area, microfi lter
Degree of separation,
microfi lter (DOP)
Sound level */
Description
Th e DC 5800c 9.2/11 kW S is driven by a two stage con-
nected turbopump with extremely high vacuum eff ekt.
Th e machine is intended for use on material transporta-
tion systems or for cleaning of abnormally heavy material.
With theese types of systems it is recommended to use a
preseparator.
Th e high vacuum eff ect can also be used in conven-tional
systems where extra long hose or pipe systems are required.
Filter cleaning is done with reverse pulse which gives excel-
lent fi lter economy.
Th e extraction system functions with negative pressure (va-
2012-01-30
50 Hz
60 Hz
1800x760x1150 mm
ca 200 kg
ca 220 kg
φ 76 mm
φ 76 mm
kPa
700 x 850 mm
40
5-50 m
5-50 m
3
3
500 m
/h
560 m
/h
40 kPa
45 kPa
9.2 kW
11 kW
20
2
2
4.8 m
4.8 m
99.9 %
99.9 %
2
2
2.5 m
2.5 m
> 99,97 %
> 99,97 %
< 75 dB(A)
< 75 dB(A) */ Sound level at 1.6 m height and 1 m distance accor-
DC 5800c 11 kW S - 9
Vacuum producer capacity
11 kW S 60 Hz
9.2 kW S
200
400
ding to DIN EN ISO 3744 in free space and at maximum
airfl ow.
cuum) that draws the air through suction casings/nozzles,
hose system, separator and fi lter system. Coarse separation
of dust occurs in the units cyclone which is a highly effi cient
separator for larger particulate. Th e fi ne dust is separated
and contained by the units fi lter system. Separated material
is collected for disposal in the plastic sack or container at
the base of the cyclone.
600
800
1000
Part No 9091-B
m
3
/h