Instructions For Putting Into Operation; Positioning; Assembling; Models With Internal Winder - STAYER WELDING MIG/MAG Série Instructions D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
• Shape the tungsten electrode only in a grinder with appropriate
guards at a safe location using necessary protection for your
face, hands and body. Do not breathe-in filings.
• Sparks may cause fire – keep inflammables far away.
THE WELDING WIRE may cause you injuries.
• Do not press the trigger of the torch until receiving these
instructions.
• Do not point the tip of the torch towards any point of your body,
other persons or any metal object when passing the wire.
MOVING PARTS may injure.
• Keep away from any moving parts such as fans.
• Keep any doors, panels, lids and guards close and in place.
• Achieve that only qualified persons remove doors, panels, lids
and guards to provide maintenance as necessary.
• Reinstall doors, panels, lids and guards after having completed
provision of maintenance and before reconnecting input power.
HIGH
FREQUENCY
interferences.
• High frequency radiation (H.F.) may interfere with radio
navigation, safety services, computers and communication
equipment.
• Make sure that only qualified persons familiarized with
electronic equipment install the equipment. The user takes
responsibility for having a trained electrician who will correct any
problem caused by the installation soon.
• Make sure that the installation receives regular checking and
maintenance.
• Keep doors and panels of a high frequency source completely
shut, keep the distance of the spark at the contact points in its
correct fixation and is grounded and protects countercurrent to
minimize the possibility of interference.
ARC WELDING may cause interference.
• Electromagnetic energy may interfere with sensitive electronic
equipment such as computers or computer-driven equipment
such as industrial robots.
• Make sure that any equipment within the welding area is
electromagnetically compatible.
• To reduce possible interference, keep welding cables as short
as possible, as close together as possible or, on the floor, if
possible.
• Place your welding operation at a distance of at least 100
meters from any electronically sensitive equipment.
• Make sure that the welding machine is installed and grounded
in accordance with this manual.
• If there still is interference, the operator has to take extraordinary
measures, such as moving the welding machine, use shielded
cables, use line filters, or shield the work area in one way or
another.
RADIATION
may
cause
ENGLISH
27
Reducing electromagnetic fields
To reduce magnetic fields (EMF) in the work area, the following
proceedings should be used:
1. Keep cables as close together as possible, by braiding them,
or joining them with sticky adhesive tape, or using a cable cover.
2. Place cables at one side and away from the operator.
3. Do not wrap or hang cables about your body.
4. Keep welding power sources and cables as far away as
practical.
5. Connect grounding clamp to the piece you are working at, as
near as possible to the weld.
In environments with increased risk of electric shock and fire,
such as in the proximity of inflammable products, explosives,
height, restricted free moving space, physical contact with
conductive parts, warm and humid environments that reduce
the electrical resistance of human skin and apparatus, observe
the risk prevention in the workplace and the national and
international provisions as pertinent.
3. INSTRUCTIONS FOR PUTTING INTO
OPERATION

3.1. Positioning

Position the machine in a safe and dry environment and with a
flat surface.

3. 2. Assembling

3.2.1 Models with internal winder

They come fully assembled.

3.2.2 Models with external winder

Power, logics and water connection with the machine is carried
out by means of the linking hose. Simply connect the positive
pole cable, the logics connector and the water circuit (MIG500BT)
located at the rear of the main machine, with the corresponding
connectors of the spooler. The negative pole connection is made
independently of the hose.
In Model MIG500BT which carries the cooling water unit for the
water-cooled torch. Refill the front tank with water and prime the
circuit if necessary.
Both models are delivered with the gas cylinder support tray.
Use the chain as delivered to secure the welding cylinder against
overturning.

3. 3. Mains connection

Welding equipment need appropriate current supply and
sufficient power to work at full capacity. The whole range is
prepared to work with certified generators that comply with the
regulations and operate properly. Power to be supplied is at
least:
MODEL
VOLTAGE
MIG 160 Multi
230, single-phase
MIG 170 Multi
230, single-phase
MIG 200 Multi
230, single-phase
27
Amperage and
MINIMUM
voltage for
RECOMMENDED
POWER,
magnetothermal or
POWER, 7KVA
differential circuit
KVA
breaker
5
7
2 poles, 230v, 32 Ah
5
7
2 poles, 230v, 32 Ah
6
7
2 poles, 230v, 32 Ah