INSTALLATION
ELECTRICAL CONNECTION
Damage to the appliance and the environment:
!
Observe the type plate. The specified voltage must match
the mains voltage.
DANGER: Electrocution
Before beginning any work on the electric installa-
tion, be sure that main breaker panel switch is „off" to
avoid any danger of electric shock. All mounting and
plumbing must be completed before proceeding with
electrical hook-up. Where required by local, state or
national electrical codes the circuit should be equipped
with a „ground fault interrupter".
DANGER: Electrocution
As with any electric appliance. failure to electrically ground
appliance may result in serious injury or death.
The appliance should be connected to a properly grounded
dedicated branch circuit of proper voltage rating. In installa-
tions with several appliances, each appliance requires an inde-
pendent circuit. Please refer to the technical data table for the
correct wire and circuit breaker size.
4˝ (100 mm)
The wire must be fed through the rubber seal located be-
tween the hot and cold water connections. Then feed wires
through strain relief clamp and tighten clamp down on wire.
The "live" wires must be connected to the slots on the terminal
block marked L and L. The ground wire must be connected to
slot marked with the ground symbol. Strain relief clamp with
screws and rubber seal are provided.
WWW.STIEBEL-ELTRON-USA.COM
10.1 Temperature setting/anti-scalding protection
Connect the lead of the electronic temperature control to posi-
tion „A1" in order to get the maximum outlet temperature of
140°F (60°C).
The maximum temperature can be limited to 109°F (43°C):
Connect the lead of the electronic temperature control to posi-
tion "A2".
Reinstall the plastic cover.
10.2 Terminal block
Consult the chart below for the recommended torque amounts on
the terminal block screws.
Screw Size (mm)
Min. Torque (N•cm)
M6
200-250
Using the proper torque specifications to secure wire to the wiring
block helps to avoid personal loss or property damage.
Min. Torque (lbf•in)
17.7-22.1
MEGABOOST |
7