Warnings and instructions

The doors must be actively closed by the operator using the preset command F03 or F04. They
do not close automatically when the train departs!
No liability can be assumed for any damage resulting from the train departing when the doors
are open (hazard spots are when trains encounter each other in curves, tunnel portals, overhead
line masts, etc.!).
A carriage with open doors is 25mm wider when measured from the track centre (permissible
clearance gauge in the width from the centre of the tract pursuant to NEM301:20mm) , the
projection measuring 32mm in the outer curves with a R2 radius!
The operation with overhead lines has been dispensed with for various reasons (car-riages are
not fitted with a pantograph).
Troubleshooting table for the carriages
Fault Pattern
Carriage does not react: neither the
doors nor the interior lighting.
Doors do not open, no door sound.
One door functions, the other does not.
The doors do not open, door sounds
audible, engine audible.
Tail lamp flickers.
Digital Waggon.indd 41
Action
Check the carriage address.
Programme the value 8 at CV8 in order to reset the
settings to the delivery state.
Programme the value 7 at CV7 in order to reset the
hardware to the delivery state.
Programme the value 7 at CV7 in order to reset the
hardware to the delivery state.
Defective gear.
Compare the running steps of your centre with the
setting in CV29.