Advanced Programming

Delete a Zone on the RS232
Interface from a RadioTouch
Controller
Press and hold the CONF and ADDR buttons for 5
seconds to enter unit configuration mode. The LED
display will begin flashing UC to alert you that the
unit has entered unit configuration mode.
Press the CONF button repeatedly until the display
shows AS. Press the OK button to begin deleting
zones.
To delete a zone, press the left scroll button until the
zone number you wish to delete is displayed. Press
the ADDR button and the display will show P with
the zone number to be programmed, and the ADDR
LED will turn on.
On the RadioTouch controller you wish to delete from
the RS232 interface zone, press and release the
PROG button. The lights will cycle up and down for
3 seconds to notify you that you are in programming
mode, and settle at 50% light output. If you are using
an RTA-RX-SW, the lights will cycle off and on. The
Status LED on the controller will be in fast blink
mode. If no lights are connected to this controller,
the status LED will be your only feedback.
On the RS232 interface, press and hold the right
scroll and OK buttons for 5 seconds. When the
controller has deleted the RS232 zone, the lights will
flash or cycle off and on. If no lights are connected to
this controller, hold the buttons until the 3 LEDs
around the display flash (approximately 5 seconds).
Note: To delete a zone from an RTA-RS232 interface
shipped before August 2002 (date code K31), press
and hold the left scroll and OK buttons.
On the controller, press the PROG button to exit
program mode. The lights will go to high end, and
the STAT LED will return to slow blink mode. If you
are using an RTA-RX-SW, the lights will cycle off and
on.
Repeat these steps to delete additional zones from
this RS232 interface.
Press and hold the CONF and ADDR buttons for 5
seconds to exit unit configuration mode. The display
will start to sequence (approximately 5 seconds).
20
RadioTouch
RTA-RS232 Programming and Operation Guide
TM
TX
RX
Press and hold for 5 seconds to enter or exit unit
configuration mode.
TX
RX
Press CONF until the LED
display reads AS.
TX
RX
Press the right scroll
button to display the
desired zone number.
R adio T ouch
120/277 V
60 Hz
TM
RT A-RX-F
16 A Max.
LISTED 243C
®
I nd . C ont . E q .
Coopersburg, PA 18036 USA
Refer to the Installers Guide for more
detailed instructions.
Consulte la Guía de Instaladores para
USA, Canada
1-800-523-9466
información más detallada.
Mexico
1-888-235-2910
Référer au Guide d'installation pour plus de
www.lutron.com
renseignements détaillés.
CONFIGURACIONES
REGLAGES
SETTINGS
PWR
STAT
PROG
100 H r /100%
ON
1
2
3
4
5
1 2
3
4 5 6 7 8
0-10
®
V
ON
1
2
3
4
5
1
2
3
4
5
6
7
8
TX
RX
Press and hold the right scroll and OK buttons on the
interface for 5 seconds.
Then press OK.
Press ADDR to display P
in the left window and
light the ADDR LED.
RadioTouch controller
(this step only)
PROG button
Status LED
R