8. Configuration via display and operating unit
8.5.2
Setting the length unit (for level measurement)
1. Open the operating menu with [↵].
Select "Basic setting" and confirm with [↵].
2. Select "Application" and confirm with [↵].
3. Select "Level" and confirm with [↵].
4. Select "Unit" and confirm with [↵].
5. Select length unit and confirm with [↵].
» Length unit is set.
8.5.3
Setting the volume unit
1. Open the operating menu with [↵].
Select "Basic setting" and confirm with [↵].
2. Select "Application" and confirm with [↵].
3. Select "Volume" and confirm with [↵].
4. Select "Scale out" and confirm with [↵].
5. Select "Unit" and confirm with [↵].
6. Select volume unit and confirm with [↵].
Volume unit: Standard units (e.g. litres, m³, ...)
■
Free input: Freely definable unit (selectable under
■
"Volume unit")
» Volume unit is set.
WIKA operating instructions, model DMSU21A
EN
35